Effects of Pump-turbine S-shaped Characteristics on Transient Behaviours: Experimental Investigation
نویسندگان
چکیده
A pumped storage stations model was set up and introduced in the previous paper. In the model station, the S-shaped characteristic curves was measured at the load rejection condition with the guide vanes stalling. Load rejection tests where guide-vane closed linearly were performed to validate the effect of the S-shaped characteristics on hydraulic transients. Load rejection experiments with different guide vane closing schemes were also performed to determine a suitable scheme considering the S-shaped characteristics. The condition of one pump turbine rejecting its load after another defined as one-after-another (OAA) load rejection was performed to validate the possibility of S-induced extreme draft tube pressure.
منابع مشابه
Effects of Pump-turbine S-shaped Characteristics on Transient Behaviours: Model Setup
Pumped storage stations undergo numerous transition processes, which make the pump turbines go through the unstable S-shaped region. The hydraulic transient in S-shaped region has normally been investigated through numerical simulations, while field experiments generally involve high risks and are difficult to perform. In this research, a pumped storage model composed of a piping system, two mo...
متن کاملThree-dimensional transient simulation of a prototype pump-turbine during normal turbine shutdown
Three-dimensional numerical simulations are carried out by commercial software STAR-CCM+ to investigate the hydraulic transient and flow behaviours of a prototype pump-turbine during the normal shutdown process. The global characteristics and pressure fluctuations are analysed as the pump-turbine runs through the turbine mode, into the turbine braking mode, and finally into the reversed pump mo...
متن کاملEffects of Valve Closing Law and Unsteady Friction Model on Damping Pressure Waves in a Network
Water-hammer is a transient condition which may occur in a network as a result of rapid or slow valve closures, pump failures, changes in turbine loading, etc. It creates high and low pressure waves which travel along the system and decay as a result of wall shear stress. Comparison o experimental and theoretical results revealed the failure of steady or quasi-steady models in correctly predict...
متن کاملEffects of Valve Closing Law and Unsteady Friction Model on Damping Pressure Waves in a Network
Water-hammer is a transient condition which may occur in a network as a result of rapid or slow valve closures, pump failures, changes in turbine loading, etc. It creates high and low pressure waves which travel along the system and decay as a result of wall shear stress. Comparison o experimental and theoretical results revealed the failure of steady or quasi-steady models in correctly predict...
متن کاملNumerical aeroelastic analysis of wind turbine NREL Phase VI Rotor
This study investigated the performance and aeroelastic characteristics of a wind turbine blade based on strongly coupled approach (two-way fluid structure interaction) to simulate the transient FSI1 responses of HAWT2. Aerodynamic response was obtained by 3D CFD-URANS approach and structural response was obtained by 3D Finite element method. Aeroelastic responses of the blade were obtained by ...
متن کامل