Analysis for carboxyhemoglobin by gas chromatography and multicomponent spectrophotometry compared.
نویسندگان
چکیده
Measurements of carboxyhemoglobin (HbCO) by gas chromatography (GC) were compared with those obtained by multicomponent spectrophotometric analysis (MCA). Correlation was good for HbCO ranges (proportion of total hemoglobin) of 1.5 to less than or equal to 5% (GC = 0.94 MCA + 0.37%, n = 25, r = 0.98); 5.0 to less than or equal to 10.0% (GC = 0.89 MCA + 0.63%, n = 19, r = 0.93); greater than 10% (GC = 1.01 MCA - 0.02%, n = 22, r = 0.99); and greater than 0% (GC = 1.01 MCA - 0.10%, n = 95, r = 1.00). The correlation is lower for the clinically normal range of 0 to less than or equal to 1.5% (GC = 0.65 MCA + 0.24%, n = 29, r = 0.87). The gas-chromatographic method is linear for HbCO proportions of 30% to as little as 0.15%. Re-analysis of blood samples after two-month storage at 4 degrees C showed that samples remained stable under these conditions.
منابع مشابه
Microanalysis of carbon monoxide in decomposed blood and hepatic tissues by headspace gas chromatography and mass spectrometry
Head-Space Gas Chromatography-Mass Spectrometry (HS-GC/MS) was used to determine blood carboxyhemoglobin (COHb%), especially in cases involving blood decomposition or death, when blood extraction is impossible. Until now, the problem eluded complete solution using forensic toxicology. Therefore a method was developed using Headspace Gas Chromatography-Mass Spectrometry (HSGC/MS), which should e...
متن کاملSuicidal inhalation of motorbike exhaust: adding new data to the literature about the contribution of gasoline in the cause of death.
We would like to alert toxicologists to the importance of testing for gasoline, and for volatile hydrocarbons in general, in deaths involving inhalation of exhaust fumes occurring in closed spaces with running motors or machinery. We present here a case of suicidal inhalation of motorbike exhaust, a mixture of carbon monoxide (CO) and gasoline vapor, by a 38-year-old female. She was found in he...
متن کاملCarbon monoxide in blood: an improved microliter blood-sample collection system, with rapid analysis by gas chromatography.
We examined the sensitive assay for carboxyhemoglobin based on reaction with K3Fe(CN)6 and gas chromatography of the liberated CO. Our improvements included increased baseline stability, shorter analysis time, and simpler standardization. EDTA-containing Vacutainer Tubes (lavender-stoppered) increase the carboxyhemoglobin content of blood stored in them. The carboxyhemoglobin content of blood s...
متن کاملCarboxyhemoglobin determined in neonatal blood with a CO-oximeter unaffected by fetal oxyhemoglobin.
Measurements of carboxyhemoglobin (COHb) for clinical purposes are routinely made with CO-oximeters. However, fetal hemoglobin (HbF) interferes with this spectrophotometric method. The manufacturer (Ciba Corning Diagnostics) of a new CO-oximeter (CCD 270) claims that COHb measurements with this instrument are insignificantly affected by HbF. We examined this claim through CO-oximeter analysis o...
متن کاملComparative determination of phenytoin by spectrophotometry, gas chromatography, liquid chromatography, enzyme immunoassay, and radioimmunoassay.
Sera from patients being treated with phenytoin were analyzed for the drug by spectrophotometry, gas chromatography, radioimmunoassay, enzyme immunoassay, and liquid chromatography. The essay values obtained were intercompared statistically. Enzyme immunoassay and liquid chromatography appear to be attractive alternatives to the more traditional methods of spectrophotometry and gas chromatograp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 33 5 شماره
صفحات -
تاریخ انتشار 1987