Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis
نویسندگان
چکیده
OBJECTIVE The purpose of this study was to compare the stability and feasibility of four fixation constructs in a posterior column acetabular fracture: one reconstruction plate, one reconstruction plate and lag screw, two reconstruction plates, and a W-shaped acetabular angular plate. METHODS Twenty embalmed cadaveric pelvises with a posterior column acetabular fractures were allocated to one of four groups: 1) a reconstruction plate, 2) a reconstruction plate with a posterior column lag screw, 3) double reconstruction plates, and 4) a W-shaped acetabular angular plate. These constructs were mechanically loaded on a testing machine, and construct stiffness values were measured. Strain gauges were utilized to measure the mechanical behavior in the condition of compressive force. RESULTS Final stiffness was not different between the two reconstruction plates (445.81±98.30 N/mm) and the W-shaped acetabular angular plate (447.43±98.45 N/mm, p = 0.524), both of which were superior to a single reconstruction plate (248.90±61.95 N/mm) and a combined plate and lag screw (326.41±94.34 N/mm). Following the fixation of the W-shaped acetabular angular plate, the strain distribution was similar to the intact condition around the acetabulum. The parameters of the W-shaped acetabular angular plate that were observed at the superior region of the acetabulum were less than those of a single reconstruction plate (p<0.05), a single reconstruction plate with lag screw (p<0.05), and two reconstruction plates (p<0.05). CONCLUSIONS The novel W-shaped acetabular angular plate fixation technique was able to provide the biomechanically stiffest construct for stabilization of a posterior column acetabular fracture; it also resulted in a partial restoration of joint loading parameters toward the intact state.
منابع مشابه
Biomechanical Analysis of the Fixation System for T-Shaped Acetabular Fracture
This study aims to evaluate the biomechanical mechanism of fixation systems in the most frequent T-shaped acetabular fracture using finite element method. The treatment of acetabular fractures was based on extensive clinical experience. Three commonly accepted rigid fixation methods (double column reconstruction plates (P × 2), anterior column plate combined with posterior column screws (P + PS...
متن کاملSingle column locking plate fixation is inadequate in two column acetabular fractures. A biomechanical analysis
BACKGROUND The objective of this study was to determine whether one can achieve stable fixation of a two column (transverse) acetabular fracture by only fixing a single column with a locking plate and unicortical locking screws. We hypothesized that a locking plate applied to the anterior column of a transverse acetabular fracture would create a construct that is more rigid than a non-locking p...
متن کاملAcetabular Fractures in the Senior Population– Epidemiology, Mortality and Treatments
Background:Management of acetabular fractures in the senior population can be one of the most challenging injuries tomanage. Furthermore, treating surgeons have a paucity of information to guide the treatment in this patient population.The purpose of this study was to determine: (1) demographic and epidemiologic data, (2) mortality rates for nonoperativecompared to operative management at diffe...
متن کاملA Novel Fixation System for Acetabular Quadrilateral Plate Fracture: A Comparative Biomechanical Study
This study aims to assess the biomechanical properties of a novel fixation system (named AFRIF) and to compare it with other five different fixation techniques for quadrilateral plate fractures. This in vitro biomechanical experiment has shown that the multidirectional titanium fixation (MTF) and pelvic brim long screws fixation (PBSF) provided the strongest fixation for quadrilateral plate fra...
متن کاملBiomechanical analysis of the acetabular buttress-plate: are complex acetabular fractures in the quadrilateral area stable after treatment with anterior construct plate-1/3 tube buttress plate fixation?
OBJECTIVE The acetabular buttress-plate has been widely used in treating difficult cases with satisfying clinical results. However, the biomechanical properties of a postoperative acetabular fracture fixed by the buttress-plate are not clear. The purpose of this study was to evaluate the biomechanical properties of stability after the anterior tube buttress-plate fixation of complex acetabular ...
متن کامل