Assessment of corneal biomechanical properties and intraocular pressure with the Ocular Response Analyzer in childhood myopia.

نویسندگان

  • Pei-Yao Chang
  • Shu-Wen Chang
  • Jiun-Yi Wang
چکیده

BACKGROUND/AIMS The authors estimated the association between corneal biomechanical properties and axial length in myopic children and verified the relationship between axial length and intraocular pressure (IOP). METHODS This cross-sectional study included 126 eyes of 63 children, aged 12.02+/-3.19 years. Corneal hysteresis (CH), corneal resistance factor (CRF), central corneal thickness (CCT) and IOP were recorded with the Reichert Ocular Response Analyzer. Axial length (AL) and anterior chamber depth (ACD) were measured by the IOLMaster, whereas corneal curvature was measured by an autorefractor. RESULTS In multivariable mixed model analysis, CH correlated significantly with AL (p<0.0001), ACD (p=0.044) and CCT (p<0.0001), but not with curvature; CRF correlated significantly with AL (p=0.004) and CCT (p<0.0001) but not ACD or curvature. The difference in CH between the two eyes of each patient correlated significantly with the difference in the AL between the two eyes (p=0.002). IOP did not correlate with age, gender or AL. CONCLUSION Lower CH and CRF were associated with longer AL but not corneal curvature. The association between lower CH and deeper ACD demonstrated the importance of CH as a determinant of ocular biometry in both the anterior and posterior segments. Differences in corneal biomechanical properties may indicate more generalised structural differences between eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Effect of Ocular Biomechanics on Intraocular Pressure Measurement in Mucopolysaccharidosis I-S (Scheie’s Syndrome)

Purpose: To study the effect of biomechanical properties of the cornea on the intraocular pressure in eyes affected with Mucopolysaccharidosis type I-S (Scheie's syndrome). Methods: Four eyes of two patients in their mid-fifties diagnosed with Scheie's syndrome were investigated for corneal biomechanical properties. The corneal biomechanical profile was assessed by the use of Ocular response an...

متن کامل

Ocular Response Analyzer

Until recently, corneal biomechanical properties could not be measured in vivo. The ocular response analyzer is a new, noninvasive device that analyses corneal biomechanical properties simply and rapidly. The ORA allows cornea compensated IOP measurements and can estimate corneal hysteresis (CH) and corneal resistance factor (CRF). It is designed to improve the accuracy of IOP measurement by us...

متن کامل

Corneal Biomechanics Determination in Healthy Myopic Subjects

Purpose. To determine the corneal biomechanical properties by using the Ocular Response Analyzer™ and to investigate potential factors associated with the corneal biomechanics in healthy myopic subjects. Methods. 135 eyes from 135 healthy myopic subjects were included in this cross-sectional observational study. Cornea hysteresis (CH), corneal resistance factor (CRF), cornea-compensated intraoc...

متن کامل

Assessment of Corneal Biomechanical Properties and Intraocular Pressure in Myopic Spanish Healthy Population

Purpose. To examine biomechanical parameters of the cornea in myopic eyes and their relationship with the degree of myopia in a western healthy population. Methods. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann correlated intraocular pressure (IOP), and corneal compensated IOP (IOPcc) were measured using the ocular response analyzer (ORA) in 312 eyes of 177 Spanish subjects...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 94 7  شماره 

صفحات  -

تاریخ انتشار 2010