Mössbauer Effect Studies of Xenon Implanted in Iron

نویسندگان

  • J. Odeurs
  • R. Coussement
  • J. De Bruyn
  • H. Pattyn
  • M. Van Rossum
چکیده

By means of the Mossbauer Effect a systematic dose and dose rate study has been performed on xenon implanted in iron. The substitutional fraction of the xenon nuclei decreases when the implantation dose is increased from 5 X 1011 atoms/cm2 to 1015 atoms/cmz. Two samples were implanted both to a dose of 5 X 1013 atoms/cm* but with a dose rate ratio of 75. The sample with the highest dose rate shows the highest substitutional fraction. To describe the evolution of an implanted system we propose a model based on the interaction of the impurities with the radiation damage during implantation. This model is consistent, at least qualitatively, with the experimental results. --f

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mössbauer Studies of Nickel-Iron Hydrotalcites

für Naturforschung in cooperation with the Max Planck Society for the Advancement of Science under a Creative Commons Attribution 4.0 International License. Dieses Werk wurde im Jahr 2013 vom Verlag Zeitschrift für Naturforschung in Zusammenarbeit mit der Max-Planck-Gesellschaft zur Förderung der Wissenschaften e.V. digitalisiert und unter folgender Lizenz veröffentlicht: Creative Commons Namen...

متن کامل

Mössbauer Studies on the Iron-ligand Binding in Hemoproteins and Their Related Compounds

The electronic structure of the heme iron in hemoproteins is characterized by its changeable valence and spin states. These features are discussed in hemoproteins and their related model compounds. The iron-ligand binding, especially the reversible dioxygen binding in myoglobin and hemoglobin is discussed in details by using the f4;issbauer spectroscopic knowledge obtained from the experiments ...

متن کامل

Computer simulation techniques to design Xenon-124 solid target for iodine-123 production

Background: Iodine-123 (123I) is regarded as one of the best radionuclides for in vivo medical studies using single-photon emission computed tomography (SPECT) due to its suitable physical property. Materials and Methods: To design a new system in order to replace cryogenically solidified xenon target by the gas one, some necessary calculations are needed to be done such as finding the excitati...

متن کامل

Quadrupole Splitting and Paramagnetic Iron Core Structure in Iron-Dextran Complexes: A Mössbauer Effect Study

M. I. Oshtrakh, V. A. Semionkin', O. B. Milder', A. B. Livshits, and A. A. Kozlov a Division of Applied Biophysics, Faculty of Physical Techniques and Devices for Quality Control, Ural State Technical University, Ekaterinburg, 620002, Russian Federation b Faculty of Experimental Physics, Ural State Technical University, Ekaterinburg, 620002, Russian Federation c Hematological Scientific Center ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -