Bacterial colonization of pellet softening reactors used during drinking water treatment.
نویسندگان
چکیده
Pellet softening reactors are used in centralized and decentralized drinking water treatment plants for the removal of calcium (hardness) through chemically induced precipitation of calcite. This is accomplished in fluidized pellet reactors, where a strong base is added to the influent to increase the pH and facilitate the process of precipitation on an added seeding material. Here we describe for the first time the opportunistic bacterial colonization of the calcite pellets in a full-scale pellet softening reactor and the functional contribution of these colonizing bacteria to the overall drinking water treatment process. ATP analysis, advanced microscopy, and community fingerprinting with denaturing gradient gel electrophoretic (DGGE) analysis were used to characterize the biomass on the pellets, while assimilable organic carbon (AOC), dissolved organic carbon, and flow cytometric analysis were used to characterize the impact of the biological processes on drinking water quality. The data revealed pellet colonization at concentrations in excess of 500 ng of ATP/g of pellet and reactor biomass concentrations as high as 220 mg of ATP/m(3) of reactor, comprising a wide variety of different microorganisms. These organisms removed as much as 60% of AOC from the water during treatment, thus contributing toward the biological stabilization of the drinking water. Notably, only a small fraction (about 60,000 cells/ml) of the bacteria in the reactors was released into the effluent under normal conditions, while the majority of the bacteria colonizing the pellets were captured in the calcite structures of the pellets and were removed as a reusable product.
منابع مشابه
Modeling and Predictive Control of Pellet Reactors for Water Softening
A nonlinear chemical/physical dynamic model in the form of partial differential equations was adopted and further developed to serve as a basis for model predictive control of a pellet reactor for drinking water softening. The model was calibrated using full-scale process measurements. A linear predictive controller based on a lineralization of the model has been designed to achieve the desired...
متن کاملModel-Based Dosing Control of a Pellet Softening Reactor
The control of a drinking-water treatment plant aims to produce the correct quantity of water, with a constant quality. Achieving constant water quality is not an obvious task, since the online water-quality measurements and possible control actions are limited. Applying model-based control improves disturbance rejection and online process optimisation. For the softening process step, the integ...
متن کاملImpacts of the reduction of nutrient levels on bacterial water quality in distribution systems.
This study evaluated the impacts of reducing nutrient levels on bacterial water quality in drinking water. Two American Water System facilities (sites NJ102a and IN610) with histories of coliform problems were involved, and each water utility received two pilot distribution systems (annular reactors). One reactor simulated the conventional treatment conditions (control), while the other reactor...
متن کاملRemoval of strontium from drinking water by conventional treatment and lime softening in bench-scale studies.
The United States Environmental Protection Agency Contaminant Candidate List 3 lists strontium as a contaminant for potential regulatory consideration in drinking water. Very limited data is available on strontium removal from drinking water and as a result, there is an immediate need for treatment information. The objective of this work is to evaluate the effectiveness of coagulation/filtratio...
متن کاملEffect of disinfectants on microbial ecology in model distribution systems.
This research was conducted to assess the impact of various disinfectants on bacterial water quality within model distribution systems (i.e. annular reactors). After colonization with non-disinfected water, annular reactors were treated with relatively low doses of chlorine (0.4 mg/l), chlorine dioxide (0.15 mg/l), or chloramines (0.9 mg/l). Under the tested conditions, bacterial inactivation v...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied and environmental microbiology
دوره 77 3 شماره
صفحات -
تاریخ انتشار 2011