Is It Time to Change Our Reference Curve for Femur Length? Using the Z-Score to Select the Best Chart in a Chinese Population
نویسندگان
چکیده
OBJECTIVE To use Z-scores to compare different charts of femur length (FL) applied to our population with the aim of identifying the most appropriate chart. METHODS A retrospective study was conducted in Beijing. Fifteen hospitals in Beijing were chosen as clusters using a systemic cluster sampling method, in which 15,194 pregnant women delivered from June 20th to November 30th, 2013. The measurements of FL in the second and third trimester were recorded, as well as the last measurement obtained before delivery. Based on the inclusion and exclusion criteria, we identified FL measurements from 19996 ultrasounds from 7194 patients between 11 and 42 weeks gestation. The FL data were then transformed into Z-scores that were calculated using three series of reference equations obtained from three reports: Leung TN, Pang MW et al (2008); Chitty LS, Altman DG et al (1994); and Papageorghiou AT et al (2014). Each Z-score distribution was presented as the mean and standard deviation (SD). Skewness and kurtosis and were compared with the standard normal distribution using the Kolmogorov-Smirnov test. The histogram of their distributions was superimposed on the non-skewed standard normal curve (mean = 0, SD = 1) to provide a direct visual impression. Finally, the sensitivity and specificity of each reference chart for identifying fetuses <5th or >95th percentile (based on the observed distribution of Z-scores) were calculated. The Youden index was also listed. A scatter diagram with the 5th, 50th, and 95th percentile curves calculated from and superimposed on each reference chart was presented to provide a visual impression. RESULTS The three Z-score distribution curves appeared to be normal, but none of them matched the expected standard normal distribution. In our study, the Papageorghiou reference curve provided the best results, with a sensitivity of 100% for identifying fetuses with measurements < 5th and > 95th percentile, and specificities of 99.9% and 81.5%, respectively. CONCLUSIONS It is important to choose an appropriate reference curve when defining what is normal. The Papageorghiou reference curve for FL seems to be the best fit for our population. Perhaps it is time to change our reference curve for femur length.
منابع مشابه
شناسایی نقطه تغییر در بردار میانگین فرآیند نرمال دومتغیره با تغییرات مونوتونیک
When a control chart shows an out-of-control condition, a search begins to identify and eliminate the root cause(s) of the process disturbance. The time when the disturbance has manifested itself to the process is referred to as change point. Identification of the change point is considered as an essential step in analyzing and eliminating the disturbance source(s) effectively. When a process...
متن کاملBayesian Estimation of the Multiple Change Points in Gamma Process Using X-bar chart
The process personnel always seek the opportunity to improve the processes. One of the essential steps for process improvement is to quickly recognize the starting time or the change point of a process disturbance. Different from the traditional normally distributed assumption for a process, this study considers a process which follows a gamma process. In addition, we consider the possibility o...
متن کاملPrediction of Gestational Age According to Fetal Femur Length
SUMMARY Determination of gestational age have several usages in obstetrics and gynecology. The relation between fetal femur length and gestational age has determined in this research using real time sonography. 1000 iranian pregnant women between 12-40 weeks of gestation with accuratic last menstrual period and with out the history of diabetes lllellitus, hypertension, renal disease and fetal ...
متن کاملEvaluating Anthropometric Dimensions of the Femur Using Direct and Indirect Methods
Introduction: The human anthropometric characteristics are surveyed in anthropology. Anthropology is used in archeology, rehabilitation and legal medicine. The purpose of this study was to determine femur which has a special place in the science of anthropometry. Methods: To measure the femur, both direct and indirect methods was used. The direct method of measuring the 113 femur in dissection...
متن کاملA Self-starting Control Chart for Simultaneous Monitoring of Mean and Variance of Simple Linear Profiles
In many processes in real practice at the start-up stages the process parameters are not known a priori and there are no initial samples or data for executing Phase I monitoring and estimating the process parameters. In addition, the practitioners are interested in using one control chart instead of two or more for monitoring location and variability of processes. In this paper, we consider a s...
متن کامل