Validation of a photoacoustic gas analyser for the measurement of functional residual capacity using multiple-breath inert gas washout.

نویسندگان

  • Sherif Gonem
  • Florian Singer
  • Steven Corkill
  • Amisha Singapuri
  • Salman Siddiqui
  • Per Gustafsson
چکیده

BACKGROUND The respiratory mass spectrometer is the current gold-standard technique for performing multiple-breath inert gas washout (MBW), but is expensive and lacks portability. A number of alternative techniques have recently been described. OBJECTIVES We aimed to validate, using an in vitro lung model, an open-circuit MBW system that utilises a portable photoacoustic gas analyser, with sulphur hexafluoride (SF6) as the inert tracer gas. METHODS An acrylic glass lung model was utilised to assess the accuracy of functional residual capacity (FRC) measurements derived from MBW. Measurements were performed in triplicate at 20 combinations of simulated FRC, tidal volume and respiratory rate. FRC measured using MBW (FRCmbw) was compared to FRC calculated from the known dimensions of the model (FRCcalc). MBW was also performed in 10 healthy subjects and 14 patients with asthma. RESULTS The MBW system measured FRC with high precision. The mean bias of FRCmbw with respect to FRCcalc was -0.4% (95% limits of agreement of -4.6 and 3.9%). The mean coefficient of variation of triplicate FRC measurements was 4.0% in vivo and 1.0% in vitro. MBW slightly underestimated low lung volumes and overestimated high lung volumes, but this did not cause a significant error in lung clearance index except at lung volumes below 1,500 ml. CONCLUSIONS The open-circuit MBW system utilising SF6 as the inert tracer gas and a photoacoustic gas analyser is both accurate and repeatable within the adult range of lung volumes. Further modifications would be required before its use in young children or infants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enhanced Photoacoustic Gas Analyser Response Time and Impact on Accuracy at Fast Ventilation Rates during Multiple Breath Washout

BACKGROUND The Innocor device contains a highly sensitive photoacoustic gas analyser that has been used to perform multiple breath washout (MBW) measurements using very low concentrations of the tracer gas SF6. Use in smaller subjects has been restricted by the requirement for a gas analyser response time of <100 ms, in order to ensure accurate estimation of lung volumes at rapid ventilation ra...

متن کامل

Moment ratio analysis of multiple breath nitrogen washout in infants with lung disease.

Measurement of lung volumes at end expiratory level and assessment of ventilation inhomogeneity is important for respiratory management in infants with lung disease. This study compared multiple breath nitrogen washout was compared with body plethysmography to measure functional residual capacity in infants and assessed ventilation inhomogeneity using mean dilution numbers and alveolar based ga...

متن کامل

Defining the appropriate waiting time between multiple-breath nitrogen washout measurements.

Static lung volume measurements allow objective assessment of total lung capacity (TLC), functional residual capacity (FRC) and residual volume, and assist in the diagnosis and management of lung disease [1, 2]. The use of gas dilution techniques, such as multiple-breath nitrogen washout (MBNW), require minimal patient cooperation and allow FRC to be determined in those individuals unable to co...

متن کامل

Multiple-breath nitrogen washout techniques: including measurements with patients on ventilators.

Definition ....................................................................... Methods for determining FRC ................................... Choice of method FRC measured by plethysmography (FRCpleth) ......... FRC measured by helium dilution (FRCHe) ............. FRC measured by nitrogen washout (FRCN2) ........... Standards for lung volume measurement by gas dilution/washout techniques ...

متن کامل

Measurement of functional residual capacity by modified multiple breath nitrogen washout for spontaneously breathing and mechanically ventilated patients.

BACKGROUND There is a need for a bedside functional residual capacity (FRC) measurement method that performs well in intensive care patients during many modes of ventilation including controlled, assisted, spontaneous, and mixed. We developed a modified multiple breath nitrogen washout method for FRC measurement that relies on end-tidal gas fractions and alveolar tidal volume measurements as in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiration; international review of thoracic diseases

دوره 87 6  شماره 

صفحات  -

تاریخ انتشار 2014