Calculation of beta-ray dose distributions from ophthalmic applicators and comparison with measurements in a model eye.
نویسندگان
چکیده
Dose distributions throughout the eye, from three types of beta-ray ophthalmic applicators, were calculated using the EGS4, ACCEPT 3.0, and other Monte Carlo codes. The applicators were those for which doses were measured in a recent international intercomparison [Med. Phys. 28, 1373 (2001)], planar applicators of 106Ru-106Rh and 90Sr-90Y and a concave 106Ru-106Rh applicator. The main purpose was to compare the results of the various codes with average experimental values. For the planar applicators, calculated and measured doses on the source axis agreed within the experimental errors (<10%) to a depth of 7 mm for 106Ru-106Rh and 5 mm for 90Sr-90Y. At greater distances the measured values are larger than those calculated. For the concave 106Ru-106Rh applicator, there was poor agreement among available calculations and only those calculated by ACCEPT 3.0 agreed with measured values. In the past, attempts have been made to derive such dose distributions simply, by integrating the appropriate point-source dose function over the source. Here, we investigated the accuracy of this procedure for encapsulated sources, by comparing such results with values calculated by Monte Carlo. An attempt was made to allow for the effects of the silver source window but no corrections were made for scattering from the source backing. In these circumstances, at 6 mm depth, the difference in the results of the two calculations was 14%-18% for a planar 106Ru-l06Rh applicator and up to 30% for the concave applicator. It becomes worse at greater depths. These errors are probably caused mainly by differences between the spectrum of beta particles transmitted by the silver window and those transmitted by a thickness of water having the same attenuation properties.
منابع مشابه
Monte Carlo simulation of two 106Ru eye plaques in a new mathematical human eye model
BEBIG Ruthenium-106 ophthalmic plaques have been used for treatment of uveal melanoma, retinoblastoma, melanoma of the iris and other special applications for many years. The plaques consist of a thin film of 106Ru, a beta emitter, encapsulated in pure silver. The present work proposes a new mathematical eye model for ophthalmic brachytherapy dosimetry. This new mod...
متن کاملDosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques
Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...
متن کاملA patch source model for treatment planning of ruthenium ophthalmic applicators.
Beta-ray emitting Ru-106/Rh-106 ophthalmic applicators have been used for close to 4 decades in the treatment of choroidal melanoma. The form factor of these applicators is a spherically concave silver bowl with an inner radius of curvature between 12 and 14 mm, and a total shell thickness of 1 mm. The radioactive nuclide is deposited in a layer 0.1 mm below the concave surface of the applicato...
متن کاملApplication of a natural diamond detector for the measurement of relative dose distributions in radiotherapy.
The suitability of a natural diamond detector with a special contact system for the measurement of relative dose distributions in selected radiotherapy applications was studied. The performance of the diamond detector was analysed by comparison with measurements using an ionization chamber and a silicon diode detector. The good stability, high response and good spatial resolution of the diamond...
متن کاملComparison of measured and Monte Carlo calculated dose distributions from “circular collimators” for radiosurgical beams
Background: Stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. A dosimetry study was performed for Elekta ‘Synergy S ’ as a dedicated Stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the BEAM/EGS4...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 28 7 شماره
صفحات -
تاریخ انتشار 2001