Triplet design as an intraocular lens for high myopia.

نویسندگان

  • C González
  • L Carretero
  • I Pascual
  • A Fimia
چکیده

We present the possibility of using a triplet as an intraocular lens (IOL). The matrix method was used to calculate the power of this triplet for high myopia. The thickness of the lens, the distances between the edges of the IOL and the endothelium, the distances between the edges of the IOL and the iris, and the nfluence of axial displacement have been analyzed. We have also compared the size, the thickness, the power, the distances between the edges of the IOL and the endothelium, and the distances between the edges of the IOL and the iris to the typical concave-plane lens that is usually implanted in highly myopic eyes. As we can see, when the anterior chamber depth is normal, our triplet presents a better geometrical form than the concave-plane lens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modern Phacoemulsification and Intraocular Lens Implantation (Refractive Lens Exchange) Is Safe and Effective in Treating High Myopia.

Improved efficacy, predictability, and safety of modern phacoemulsification have resulted in cataract surgery being considered as a refractive procedure. Refractive lens exchange by definition is a surgery aimed at replacing the cataractous or clear crystalline lens with an intraocular lens (IOL) in cases of high ametropia. The excellent intraocular optics of this procedure provide a better vis...

متن کامل

Posterior chamber phakic intraocular lens implantation for high myopia.

OBJECTIVE To evaluate the efficacy, safety and stability of posterior chamber phakic intraocular lens (PIOLs) implantation for the correction of high myopia. METHODS Thirty-nine eyes of twenty patients with high myopia (between -11.75 and -25.75 diopters) had a posterior chamber PIOL (Staar ICL) implanted. During 6 - 48 months' follow-up, visual acuity, refraction, intraocular pressure (IOP),...

متن کامل

Evaluation of Phakic Posterior Chamber Intraocular Implantable Contact Lens for High Myopia

Purpose: To evaluate efficacy, predictability and safety of the surgical correction of high myopia using the phakic posterior chamber implantable collamer lens. Design: A prospective, nonrandomized, non-comparative interventional case series. Participants: Twenty seven eyes of fifteen patients aged from 20 to 46 years having high myopia were included. Intervention: STAAR modified collamer impla...

متن کامل

Minus Piggyback Lens Overlaying ReSTOR® Multifocal Lens in High Myopia

BACKGROUND We report the case of a 40-year-old female patient treated with implantation of the Acrysof® IQ ReSTOR® lens (Alcon, Fort Worth, Tex., USA) with overlaying Acrysof EXpand® minus piggyback lens (Alcon). METHODS The patient had high myopia and was diagnosed with presbyopia and bilateral posterior subcapsular cataract. She desired to be spectacle-free and opted to undergo bilateral pl...

متن کامل

of ultra - high myopia in phakic eyes . chamber lens implantation for the correction Retinal detachment following anterior

The development of retinal detachment is reported in three eyes, of two patients, following implantation of an anterior chamber intraocular lens (AC-IOL) in phakic eyes for the correction of ultra-high myopia. The presence ofan AC-IOL may hamper the identification of retinal breaks and removal of the intraocular lens may prove necessary to improve visualisation. Shallowing of the anterior chamb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 34 16  شماره 

صفحات  -

تاریخ انتشار 1995