Ventricular arrhythmias after left ventricular assist device implantation.
نویسندگان
چکیده
BACKGROUND Left ventricular assist devices (LVADs) have been used as a bridge to cardiac transplantation and as destination therapy in patients with advanced heart failure. The period after LVAD support is associated with ventricular arrhythmias (VAs) despite ventricular unloading and such VAs can have a detrimental effect on survival. Despite the increasing use of LVAD, little is known regarding post-LVAD VAs at the molecular level and in vivo. METHODS Forty-two patients who received LVAD over a 24-month period were evaluated and grouped on the basis of the presence or absence of VAs during LVAD support. We completed a comparative microarray analyses between six patients who developed ventricular tachycardia (VT) or ventricular fibrillation (VF) after LVAD support and six patients who did not develop VAs after LVAD. RESULTS VAs occurred in 15 patients (35.7%) during LVAD support at a median post-LVAD day of 25.2. VAs were strongly associated with nonusage of a beta-blocker post-LVAD (odds ratio of 7.04, P-value = 0.001). Analysis of a subset of patients who had VT or VF after LVAD placement showed a decrease in the expression of connexin 43 (0.48 +/- 0.07), Na+/K+-ATPase (0.60 +/- 0.05), and voltage-gated K+ channel Kv4.3 (0.42 +/- 0.04), and an increase in Na+/Ca2+ exchanger (2.2 +/- 0.4) and the structural genes: Titin (2.1 +/- 0.2), laminin (1.7 +/- 0.4), calsequestrin (1.8 +/- 0.5), skeletal muscle isoform of troponin T (5.1 +/- 0.9), and skeletal muscle isoform of troponin I (3.9 +/- 0.7). CONCLUSION After LVAD, the increased risk of VAs is strongly associated with nonusage of beta-blocker postoperatively.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملDesign an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملDual-chamber pacemaker implantation with left ventricular pacing in a patient with a right ventricular assist device.
This is a case of a patient requiring pacemaker support after right ventricular assist device (RVAD) implantation. Due to complete heart blockafter right ventricular infarction, a pacemakerwith anatrial leadandaventricular lead into thecoronarysinuswas implanted.Although RVAD patients requiring pacemakers lack the typical RV implantation site for the ventricular lead, the coronary sinus can be ...
متن کاملImprovement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization
In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...
متن کاملUse of implantable cardioverter defibrillators in patients with left ventricular assist devices.
Patients with left ventricular assist devices (LVADs) are at high risk of sustained ventricular arrhythmias, but these may be remarkably well tolerated and the association with sudden death is unclear. Many patients who receive an LVAD already have an implantable cardioverter defibrillator (ICD). While it is standard practice to reactivate a previously implanted ICD in an LVAD recipient, this s...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 31 10 شماره
صفحات -
تاریخ انتشار 2008