The effect of zirconia and titanium implant abutments on light reflection of the supporting soft tissues.
نویسندگان
چکیده
OBJECTIVES To determine the difference in light reflection of oral mucosa covering titanium (Ti) or zirconia (ZrO(2)) abutments as it relates to the thickness of the covering mucosa. MATERIAL AND METHODS Fifteen anterior implants (Astra Osseo speed(®)) in 11 patients were fitted with a Ti or a ZrO(2) abutment (cross-over, within-subject comparison). Hyper-spectral images were taken with a camera fitted on a surgical microscope. High-resolution images with 70 nm interval between 440 and 720 nm were obtained within 30 s (1392 × 1024 pixels). Black- and white-point reference was used for spatial and spectral normalization as well as correction for motion during exposure. Reflection spectra were extracted from the image on a line mid-buccal of the implant, starting 1 mm above the soft tissue continuing up to 3 mm apically. RESULTS Median soft tissue height is 2.3 mm (min: 1.2 mm and max: 3.1 mm). The buccal mucosa rapidly increases in the thickness, when moving apically. At 2.2 mm, thickness is 3 mm. No perceivable difference between the Ti and ZrO(2) abutment can be observed when the thickness of the mucosa is 2±0.1 mm (95% confidence interval) or more. CONCLUSION It is expected that the difference in light reflection of soft tissue covering Ti or ZrO(2) abutments is no longer noticeable for the human eye when the mucosa thickness exceeds 2 mm. Haemoglobin peaks in the reflection spectrum can be observed and make hyper-spectral imaging a practical and useful tool for measuring soft tissue health.
منابع مشابه
Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro
Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...
متن کاملComparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...
متن کاملComparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study
Abstract Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...
متن کاملAnalysis of the peri-implant soft tissues in contact with zirconia abutments: an evidence-based literature review.
AIM The aim of this study is to evaluate through a literature review, the soft tissue response in contact with zirconia abutments, including case reports comparing prosthetics rehabilitations with zirconia and titanium abutments upto 3 years of follow-up as well as the factors that should be considered on implant's abutment selection. BACKGROUND Metallic abutments can provide grayish color wh...
متن کاملمقایسه مقاومت شکست و نوع شکست اباتمنتهای زیرکونیایی مختلف در مقایسه با اباتمنتهای تیتانیومی
Background and Aims: One of the decisive factors on the final esthetic results of implant treatment is the abutment material. Ceramic abutments are nowadays very popular in this regard. The purpose of this study was to compare the fracture resistance of three zirconia abutments with titanium abutment. Materials and Methods: Four groups of abutments (five specimens in each) were prepared. The a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical oral implants research
دوره 22 10 شماره
صفحات -
تاریخ انتشار 2011