A system and methodologies for absolute quantum efficiency measurements from the vacuum ultraviolet through the near infrared.
نویسندگان
چکیده
In this paper we present our system design and methodology for making absolute quantum efficiency (QE) measurements through the vacuum ultraviolet (VUV) and verify the system with delta-doped silicon CCDs. Delta-doped detectors provide an excellent platform to validate measurements through the VUV due to their enhanced UV response. The requirements for measuring QE through the VUV are more strenuous than measurements in the near UV and necessitate, among other things, the use of a vacuum monochromator, good dewar chamber vacuum to prevent on-chip condensation, and more stringent handling requirements.
منابع مشابه
Absolute Flux Calibrated Spectrum of Vega
An absolute flux calibrated reference spectrum of Vega, the primary calibration standard in the optical, is presented. The spectrum covers the entire 0.12 to 2.6 microns wavelength. The ultraviolet spectrum is based on IUE measurements. The optical and near-infrared up to 1.05 microns consists of Hayes (1985) average spectrum. A model spectrum normalized to Hayes (1985) Johnson V flux covers th...
متن کاملLarge Vacuum Rabi Splitting in a Single Nitride-Based Quantum WellMicrocavity
Here, we report a theoretical detailed study of Vacuum Rabi Splitting (VRS) in the system of Nitride Single Quantum Well (SQW) within a semiconductor microcavity. Distributed Bragg Reflectors (DBRs) containing ZnTe/ZnSe multilayers including GaAs microcavity and ( SQW at the center of microcavity, has been considered. Upper and lower exciton-polariton branches obtaine...
متن کاملTHE 0.12 2.5 m ABSOLUTE FLUX DISTRIBUTION OF THE SUN FOR COMPARISON WITH SOLAR ANALOG STARS
An absolute ux calibrated reference spectrum of the Sun covering the 0.12 to 2.5 m wavelength range is presented. The ultraviolet and optical spectrum is based on absolute ux measurements from satellites and from the ground. The near-infrared spectrum is based on measurements using the NASA CV-990 aircraft and on a model spectrum. The synthetic optical and near-infrared magnitudes of the absolu...
متن کاملEvaluation of Energy Consumption of Potato Slices Drying Using Vacuum-Infrared Method
Objective: The main objective pursued in this paper is to investigate the energy consumption for drying of potato slices using vacuum-infrared drying method. Methods: Drying of potato slices with the thicknesses of 1, 2 and 3 mm were conducted at vacuum levels of zero (without vacuum), 20, 80 and 140 mm [Hg], infrared radiation at power levels of 100, 150 and 200 W in the three repetition. Resu...
متن کاملEvaluation of Energy Consumption of Potato Slices Drying Using Vacuum-Infrared Method
Objective: The main objective pursued in this paper is to investigate the energy consumption for drying of potato slices using vacuum-infrared drying method. Methods: Drying of potato slices with the thicknesses of 1, 2 and 3 mm were conducted at vacuum levels of zero (without vacuum), 20, 80 and 140 mm [Hg], infrared radiation at power levels of 100, 150 and 200 W in the three repetition. Resu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 82 4 شماره
صفحات -
تاریخ انتشار 2011