Room decontamination with UV radiation.

نویسندگان

  • William A Rutala
  • Maria F Gergen
  • David J Weber
چکیده

OBJECTIVE To determine the effectiveness of a UV-C-emitting device to eliminate clinically important nosocomial pathogens in a contaminated hospital room. METHODS This study was carried out in a standard but empty hospital room (phase 1) and in a room previously occupied by a patient with methicillin-resistant Staphylococcus aureus (MRSA) or vancomycin-resistant Enterococcus (VRE) infection (phase 2) in an acute care tertiary hospital in North Carolina from January 21 through September 21, 2009. During phase 1, 8 x 8 cm Formica sheets contaminated with approximately 10(4)-10(5) organisms of MRSA, VRE, multidrug-resistant (MDR) Acinetobacter baumannii, or Clostridium difficile spores were placed in a hospital room, both in direct line of sight of the UV-C device and behind objects. After timed exposure, the presence of the microbes was assessed. During phase 2, specific sites in rooms that had housed patients with MRSA or VRE infection were sampled before and after UV-C irradiation. After timed exposure, the presence of MRSA and VRE and total colony counts were assessed. RESULTS In our test room, the effectiveness of UV-C radiation in reducing the counts of vegetative bacteria on surfaces was more than 99.9% within 15 minutes, and the reduction in C. difficile spores was 99.8% within 50 minutes. In rooms occupied by patients with MRSA, UV-C irradiation of approximately 15 minutes duration resulted in a decrease in total CFUs per plate (mean, 384 CFUs vs 19 CFUs; P < .001), in the number of samples positive for MRSA (81 [20.3%] of 400 plates vs 2 [0.5%] of 400 plates; P < .001), and in MRSA counts per MRSA-positive plate (mean, 37 CFUs vs 2 CFUs; P < .001). CONCLUSIONS This UV-C device was effective in eliminating vegetative bacteria on contaminated surfaces both in the line of sight and behind objects within approximately 15 minutes and in eliminating C. difficile spores within 50 minutes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Triggering Germination Represents a Novel Strategy to Enhance Killing of Clostridium difficile Spores

BACKGROUND Clostridium difficile is an anaerobic, spore-forming bacterium that is the most common cause of healthcare-associated diarrhea in developed countries. Control of C. difficile is challenging because the spores are resistant to killing by alcohol-based hand hygiene products, antimicrobial soaps, and most disinfectants. Although initiation of germination has been shown to increase susce...

متن کامل

Rapid hospital room decontamination using ultraviolet (UV) light with a nanostructured UV-reflective wall coating.

We tested the ability of an ultraviolet C (UV-C)-reflective wall coating to reduce the time necessary to decontaminate a room using a UV-C-emitting device (Tru-D SmartUVC). The reflective wall coating provided the following time reductions for decontamination: for methicillin-resistant Staphylococcus aureus, from 25 minutes 13 seconds to 5 minutes 3 seconds ([Formula: see text]), and for Clostr...

متن کامل

Study on Catalytic and Photocatalytic Decontamination of (2-Chloroethyl) Phenyl Sulfide with Nano-TiO2

Catalytic and photocatalytic reactions of (2-chloroethyl) phenyl sulfide (2-CEPS), a mimic of bis (2-chloroethyl)  sulfide (i.e. Sulfur mustard) were studied on the surfaces of titanium oxide. TiO2 nanoparticles (anatase, rutile and mixture of 80% anatase/20% rutile) along with bulk TiO2 were tested as reactive sorbents for reaction of 2-CEPS at room temperature (25±0.5°C). Reactions were monit...

متن کامل

Room decontamination using an ultraviolet-C device with short ultraviolet exposure time.

Results:  UV-C Technology effectively reduces environmental contamination and should be considered when environmental transmission is significant.  The Optimum UV TM device achieved an overall 3.56-log10 reduction for MRSA in 5 minutes and an overall 2.78-log10 reduction for C. difficile spores in 10 minutes in typical patient rooms (not treated with UV reflective wall coating).  When the pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Infection control and hospital epidemiology

دوره 31 10  شماره 

صفحات  -

تاریخ انتشار 2010