Shear modulus data for the human lens determined from a spinning lens test

نویسندگان

  • G.S. Wilde
  • H.J. Burd
  • S.J. Judge
چکیده

The paper describes a program of mechanical testing on donated human eye bank lenses. The principal purpose of the tests was to obtain experimental data on the shear modulus of the lens for use in future computational models of the accommodation process. Testing was conducted using a procedure in which deformations are induced in the lens by spinning it about its polar axis. Shear modulus data were inferred from these observed deformations by means of a finite element inverse analysis procedure in which the spatial variation of the shear modulus within the lens is represented by an appropriate function (see Burd et al., 2011 for a detailed specification of the design of the spinning lens test rig, experimental protocols and associated data analysis procedures that were employed in the tests). Inferred data on lens shear modulus are presented for a set of twenty-nine lenses in the age range 12 years to 58 years. The lenses were tested between 47 h and 110 h from the time of death (average post-mortem time 74 h). Care was taken to exclude any lenses that had been affected by excessive post-mortem swelling, or any lenses that had suffered mechanical damage during storage, transit or the testing process. The experimental data on shear modulus indicate that, for young lenses, the cortex is stiffer than the nucleus. The shear modulus of the nucleus and cortex both increase with increasing age. The shear modulus of the nucleus increases more rapidly than the cortex with the consequence that from an age of about 45 years onwards the nucleus is stiffer than the cortex. The principal shear modulus data presented in the paper were obtained by testing at a rotational speed of 1,000 rpm. Supplementary tests were conducted at rotational speeds of 700 rpm and 1,400 rpm. The results from these supplementary tests are in good agreement with the data obtained from the principal 1,000 rpm tests. Studies on the possible effects of lens drying during the test suggested that this factor is unlikely to have led to significant errors in the experimental determination of the shear modulus. The shear modulus data presented in the paper are used to develop 'age-stiffness' models to represent the shear modulus of the lens as a function of age. These models are in a form that may be readily incorporated in a finite element model of the accommodation process. A comparison is attempted between the shear modulus data presented in the current paper and equivalent data published by previous authors. This comparison highlights various limitations and inconsistencies in the data sets.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Can reliable values of Young’s modulus be deduced from Fisher’s (1971) spinning lens measurements?

The current textbook view of the causes of presbyopia rests very largely on a series of experiments reported by R.F. Fisher some three decades ago, and in particular on the values of lens Young's modulus inferred from the deformation caused by spinning excised lenses about their optical axis (Fisher 1971) We studied the extent to which inferred values of Young's modulus are influenced by assump...

متن کامل

Mechanical properties of the human posterior lens capsule.

PURPOSE To investigate mechanical properties of the human posterior lens capsule. METHODS Twenty-five human donor eyes were obtained from an eye bank. The age of the donors ranged from 1 to 94 years. Test specimens were prepared as tissue rings from posterior lens capsules by means of excimer laser. Capsular thickness was measured microscopically as the difference in focus between microspheru...

متن کامل

A clinical decision support system for contact lens evaluation

Background: Contact lenses are transparent, thin plastic disks that cover the surface of the cornea. Appropriate lens prescription should be performed properly by an expert to provide better visual acuity and reduce side effects. The lens administration is a multi-stage, complex and time-consuming process involving many considerations. The purpose of this study was to develop a decision support...

متن کامل

Oral Morphine Consumption Reduces Lens Development in Rat Embryos

Introduction: Consumption of morphine, during pregnancy, in addition to inducing defects in the mother’s nervous system function, caused defects or delays in the formation and evolution of embryonic visual system. In the present study, changes in lens development were assessed in embryos exposed to morphine in utero. Methods: Female Wistar rats (250-300 g) were mated with male rats and pregnanc...

متن کامل

In Vivo Brillouin Analysis of the Aging Crystalline Lens

Purpose To analyze the age dependence of the longitudinal modulus of the crystalline lens in vivo using Brillouin scattering data in healthy subjects. Methods Brillouin scans were performed along the crystalline lens in 56 eyes from 30 healthy subjects aged from 19 to 63 years. Longitudinal elastic modulus was acquired along the sagittal axis of the lens with a transverse and axial resolution...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 97  شماره 

صفحات  -

تاریخ انتشار 2012