Accuracy of cardiac PET imaging using post-injection transmission scan.

نویسندگان

  • Tatsuya Yoneyama
  • Ichiro Matsunari
  • Sugako Kanayama
  • Masamichi Matsudaira
  • Kenichi Nakajima
  • Junichi Taki
  • Stephan G Nekolla
  • Kinichi Hisada
  • Norihisa Tonami
چکیده

UNLABELLED The purpose of this study was to investigate the accuracy of cardiac PET with post-injection transmission scans. METHODS We performed a phantom study using 18F solution as well as 13N-ammonia PET study of ten patients. The average activities of no myocardial defect phantom model were estimated, and myocardial defect sizes of 12 phantom models were measured by pre- and post-injection transmission methods at various 18F activities. In 13N-ammonia PET at rest and during adenosine triphosphate (ATP) stress studies, measured defect sizes were compared between both methods. RESULTS The ratios of average activity estimated by both methods (post/pre value) were almost 1.00 at each 18F activity and segment. Measured defect sizes by both methods showed an excellent correlation with true defect sizes (r = 0.98, p < 0.01 for pre vs. true value: r = 0.98, p < 0.01 for post vs. true value). The mean absolute errors of measurements were minimal up to 3.5% LV, and were similar between both methods. In 13N-ammonia PET, measured defect sizes by both methods also showed a good correlation (r = 0.97, p < 0.01). CONCLUSION The results indicate that cardiac PET imaging with post-injection transmission scan provides information on myocardial tracer activity as well as myocardial defect size as does conventional pre-injection transmission method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of extra-cardiac hypermetabolic foci by [18F]FDG PET/CT in case of infective endocarditis and post antibiotic therapy response assessment

The diagnosis of prosthetic valve endocarditis continues to present a diagnostic challenge, due to the lower sensitivity of the modified Duke criteria and a higher percentage of negative or inconclusive echocardiography results. Diagnostic delay might result in significant morbidity/mortality. Imaging modalities like 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography/comput...

متن کامل

Factors influencing the pattern and intensity of myocardial 18F-FDG uptake in oncologic PET-CT imaging

Introduction:Myocardial 18F-FDG uptake is highly variable in oncologic whole body 18F-FDG PET/CT studies, ranging from quite intense to minimal distribution. Intense or heterogeneous myocardial 18F-FDG uptake is undesirable as it may interfere with the visual or quantitative evaluation of tumoral invasion and metastases in pericardium, myocardiu...

متن کامل

Diagnostic uncertainty of isolated skull lesion in prostate cancer- Role of SPECT/CT

Skeletal involvement is the second most common site of metastases after lymph nodal metastases in patients with prostate cancer. The skeletal metastases from prostate cancer are osteoblastic in nature and show increased tracer avidity on the bone scan. Focal tracer avid lesion in skeleton especially in skull requires the careful examination by further investigation. The patients with skull meta...

متن کامل

Sensitivity of gallium scintigraphy for evaluation of recurrent lymphoma: Comparison of planar and SPECT imaging

  Introduction: Although PET scanning using F-18[FDG] is considered the superior radiotracer for tumnor imaging, Gallium-67 is still in use for some malignancies such as lymphoma and hepatoma. One of the strategies to improve the diagnostic accuracy of Gallium is to perform SPECT which is reported to be more sensitive compared to planar imaging. In this study we compa...

متن کامل

Uncertainties in effective dose estimation for CT transmission scan in total body PET-CT imaging with Auto mA3D tube current modulation

Background: Positron Emission Tomography-Computed Tomography (PET-CT) is a useful hybrid imaging modality in the diagnosis of various malignancies. This modality imposes almost 20 mSv radiation dose to the patient. The purpose of the present study was to evaluate the uncertainties in calculated CT effective dose in TUBE CURRENT MODULATION-activated scans by Impact-Dose software.  Materials and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 19 2  شماره 

صفحات  -

تاریخ انتشار 2005