A continuous He cryostat with pulse-tube pre-cooling and optical access

نویسندگان

  • J. C. Burton
  • E. Van Cleve
  • P. Taborek
چکیده

Please cite this article in press as: Burton JC doi:10.1016/j.cryogenics.2011.03.001 We have designed and constructed a continuously operating He cryostat with windows for laser ablation and spectroscopy. A two-stage pulse-tube refrigerator cools two platforms to base temperatures of approximately 40 K and 4 K respectively. The platforms are equipped with heat exchangers that cool separate streams of He and He. The He stream is used to run a thermally isolated evaporative refrigerator with a base temperature of approximately 1.5 K and a cooling power of 20 mW. The He refrigerator is used to condense He, which is used to run a He evaporative refrigerator on the experimental cell. The cryostat runs continuously at temperatures from 10 K to 0.4 K with a cooling power of 1.5 mW at 0.5 K. 2011 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modular cryostat for ion trapping with surface-electrode ion traps.

We present a simple cryostat purpose built for use with surface-electrode ion traps, designed around an affordable, large cooling power commercial pulse tube refrigerator. A modular vacuum enclosure with a single vacuum space facilitates interior access and enables rapid turnaround and flexibility for future modifications. Long rectangular windows provide nearly 360° of optical access in the pl...

متن کامل

Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals

Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...

متن کامل

A continuous dry 300 mK cooler for THz sensing applications.

We describe and demonstrate the automated operation of a novel cryostat design that is capable of maintaining an unloaded base temperature of less than 300 mK continuously, without the need to recycle the gases within the final cold head, as is the case for conventional single shot sorption pumped (3)He cooling systems. This closed dry system uses only 5 l of (3)He gas, making this an economica...

متن کامل

Influence of Interface Thermal Resistance on Relaxation Dynamics of Metal-Dielectric Nanocomposite Materials under Ultrafast Pulse Laser Excitation

Nanocomposite materials, including noble metal nanoparticles embedded in a dielectric host medium, are interesting because of their optical properties linked to surface plasmon resonance phenomena. For studding of nonlinear optical properties and/or energy transfer process, these materials may be excited by ultrashort pulse laser with a temporal width varying from some femtoseconds to some hund...

متن کامل

Studies of Superfluid Stirling and Pulse Tube

There is a niche for a sub-Kelvin cryogenic refrigeration unit that is simple, efficient, and does not require gravity. The superfluid Stirling refrigerator was developed in response to this demand. The refrigerator has cooled to 168 mK while exhausting heat at 383 mK, demonstrating the potential to cool to temperatures well below that attainable with a continuous 3He evaporation refrigerator. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011