Acetabular Placement Accuracy With the Direct Anterior Approach Freehand Technique.

نویسندگان

  • Melissa C Soderquist
  • Ryan Scully
  • Anthony S Unger
چکیده

BACKGROUND Acetabular cup placement in total hip arthroplasty (THA) has been recognized as an important factor in operative success, and accurate cup placement has been the impetus for novel medical technologies. METHODS This article examines the cup placement in 955 THAs using a freehand Direct Anterior Approach on a standard operating table. Acetabular anteversion and inclination were determined using the circle theorem. Measurements were divided into safe zone placement determined by Callanan et al as 5°-25° for anteversion and 30°-45° for inclination, as well as by Lewinnek et al as 5°-25° for anteversion and 30°-50° for inclination. Dislocation rate was determined and correlated to safe zone placement. RESULTS Although technology has advanced for cup placement, this investigation shows that a freehand technique demonstrates 0.31% dislocation after THA with an accuracy of 85% for the Lewinnek safe zone and 61% for Callanan, potentially because of the sparing of the posterior hip capsule. CONCLUSION The direct anterior approach to the hip on a regular operating table is safe and reliable. Our results demonstrate improvement in cup positioning compared with other freehand techniques. Surgeon awareness and control of the position of the pelvis within space optimizes acetabular component accuracy and precision without the need for special equipment, such as intraoperative fluoroscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Does fluoroscopy improve acetabular component placement in total hip arthroplasty?

BACKGROUND The success of THA largely depends on correct placement of the individual components. Traditionally, these have been placed freehand using anatomic landmarks, but studies have shown poor accuracy with this method. QUESTIONS/PURPOSES Specifically, we asked (1) does using fluoroscopy lead to more accurate and greater likelihood of cup placement with the Lewinnek safe zone than does f...

متن کامل

Fluoroscopic imaging of acetabular cup position during THA through a direct anterior approach.

Mobile image intensifiers are more readily used to assess acetabular cup placement when performing a total hip arthroplasty through a direct anterior approach. However, patient positioning affects pelvic tilt and rotation, which in turn requires proper C-arm fluoroscopy adjustments for image interpretation. The authors provide insight into the interpretation of acetabular cup positioning based ...

متن کامل

Can a Drill Guide Improve the Coracoid Graft Placement During the Latarjet Procedure? A Prospective Comparative Study With the Freehand Technique

Background One of the factors that can affect the success of the Latarjet procedure is accurate coracoid graft (CG) placement. Hypothesis The use of a guide can improve placement of the CG and screw positioning in the sagittal and axial planes as compared with the classic open ("freehand") technique. Study Design Cohort study; Level of evidence, 2. Methods A total of 49 patients who under...

متن کامل

Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation?

In a prospective randomised clinical study acetabular components were implanted either freehand (n = 30) or using CT-based (n = 30) or imageless navigation (n = 30). The position of the component was determined post-operatively on CT scans of the pelvis. Following conventional freehand placement of the acetabular component, only 14 of the 30 were within the safe zone as defined by Lewinnek et a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 32 9  شماره 

صفحات  -

تاریخ انتشار 2017