A near infrared spectroscopy-based test of calf muscle function in patients with peripheral arterial disease.

نویسندگان

  • Brian Lindegaard Pedersen
  • Niels Bækgaard
  • Bjørn Quistorff
چکیده

Background The study aims to test a new, simple, and reliable apparatus and procedure for the diagnostics and treatment evaluation of peripheral arterial disease (PAD). The test apparatus involves near infrared spectroscopy (NIRS) of a main part of the lower leg muscles during isometric flexion and extension of the ankle joint performed with the foot strapped in a specially designed pedal ergometer. Design To evaluate the reproducibility of the new test compared with an existing testing method of treadmill walking. Methods Eleven patients participated in the study: nine patients with claudication and two age-matched patients without claudication. Each patient was tested with an isometric ergometer pedal test and a treadmill test applying NIRS measurements of the anterior tibial and the gastrocnemius muscles (GAS). Tests were repeated three times with randomly selected intervals between individual test runs. Intraclass correlation constant (ICC) was used to describe reproducibility. The ICC was calculated using the area under the NIRS oxygenated hemoglobin (Hbox) curve, the initial velocity of the Hbox recovery curve, force measurements, and walking time. Results The ICC of the GAS was between 0.92-0.95 (foot-pedal) and 0.70-0.98 (tread mill) and of the anterior tibial muscle was between 0.87-0.96 (foot-pedal) and 0.67-0.79 (tread mill). Conclusion In this study, we contribute a new apparatus and test protocol for peripheral arterial disease (PAD) applying NIRS technique and controlled physical activity to evaluate the degree of muscle oxygenation under specific functionally relevant conditions. Thus, we have developed a clinically applicable "easy-to-do" exercise test of patients with chronic PAD which show high reproducibility.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraoperative evaluation of revascularization effect on ischemic muscle hemodynamics using near-infrared diffuse optical spectroscopies.

Arterial revascularization in patients with peripheral arterial disease (PAD) reestablishes large arterial blood supply to the ischemic muscles in lower extremities via bypass grafts or percutaneous transluminal angioplasty (PTA). Currently no gold standard is available for assessment of revascularization effects in lower extremity muscles. This study tests a novel near-infrared diffuse correla...

متن کامل

Impaired exercise-induced blood volume in type 2 diabetes with or without peripheral arterial disease measured by continuous-wave near-infrared spectroscopy.

OBJECTIVE Diabetes is a significant risk factor for peripheral arterial disease (PAD) and is associated with accelerated atherosclerosis and limb loss. However, the pathophysiology involved in PAD is unclear. This study was conducted to evaluate the hemodynamic response to exercise of patients with and without diabetes and PAD. RESEARCH DESIGN AND METHODS The hemodynamic response in calf musc...

متن کامل

Peripheral Muscle Near-Infrared Spectroscopy in Neonates: Ready for Clinical Use? A Systematic Qualitative Review of the Literature.

BACKGROUND Peripheral muscle near-infrared spectroscopy (NIRS) measurements are of increasing interest especially in the care of critically ill patients. OBJECTIVE The aim was to perform a systematic qualitative review on peripheral muscle NIRS measurements in the clinical care of term and preterm neonates. METHODS A systematic search of PubMed and Ovid Embase was performed using the follow...

متن کامل

Quantitative near-infrared spectroscopy on patients with peripheral vascular disease

We have used near-infrared spectroscopy to measure the hemoglobin saturation at rest and during exercise on patients affected by peripheral vascular disease (PVD). The instrument used in our study is a frequency-domain tissue oximeter which employs intensity modulated (110 MHz) laser diodes. We examined 9 subjects, 3 of which were controls and 6 were patients affected by stage II PVD. The optic...

متن کامل

Muscle mitochondrial function in patients with type 2 diabetes mellitus and peripheral arterial disease: implications in vascular surgery.

OBJECTIVES (1) To review the available information on mitochondrial function in type 2 diabetes mellitus (T2DM) and peripheral arterial disease (PAD) obtained by non-invasive phosphorus magnetic resonance spectroscopy ((31)PMRS), near-infrared spectroscopy (NIRS) in vivo and respirometry on mitochondria isolated from muscle biopsies in vitro (2) to evaluate the usefulness of such data in the di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of angiology : official publication of the International College of Angiology, Inc

دوره 24 1  شماره 

صفحات  -

تاریخ انتشار 2015