The ion sensitive field effect transistor (ISFET) pH electrode: a new sensor for long term ambulatory pH monitoring.
نویسندگان
چکیده
Intraluminal pH monitoring in man should be performed with disposable multichannel assemblies that allow recordings at multiple sites and prevent transmission of infection. Currently available glass electrodes are unsuitable for this purpose because of their size and price. We have thus constructed and tested a small, combined ion sensitive field effect transistor (ISFET) pH electrode incorporating an integral reference electrode. In vitro studies showed that both ISFET and glass electrodes (440-M4, Ingold, Switzerland) have a linear response over the pH range 1.3-8.0 and that they are comparable with regard to response time and 24 hour drift. Twenty one hour intragastric pH recordings were performed simultaneously in eight healthy volunteers using a glass electrode and an ISFET electrode, placed no more than 2 mm apart in a combined assembly. This was located in the gastric corpus under fluoroscopic control. The 21 hour pH curves recorded by each electrode type showed identical patterns: an early morning rise in pH with three meal-associated pH peaks lasting for about two to three hours. The means of the 21 hour pH medians were 2.09 and 2.07 as measured by the glass and the ISFET electrodes respectively. Thus, ISFETs are suitable for the construction of inexpensive and hence disposable multichannel pH monitoring assemblies of small diameter. Provided that they can be produced in large numbers with appropriate technical support, ISFETs have the potential to replace glass electrodes for long term monitoring of gastrointestinal luminal acidity.
منابع مشابه
Multimodal probe based on ISFET electrochemical microsensors for in-situ monitoring of soil nutrients in agriculture
We report the design of a silicon chip dedicated to the in-situ monitoring of soil nitrogen cycle in wheat crop. Our study shows that ion-sensitive field effect transistor (ISFET) microsensors are suitable for quick on-site or long-term analysis of nutrients measured directly in soil as opposed to soil extracts analysis. Our pH-ISFET recorded soil pH for six months with results in good accordan...
متن کاملMetal Oxides and Ion-Exchanging Surfaces as pH Sensors in Liquids: State-of-the-Art and Outlook
Novel applications of online pH determinations at temperatures from -35 °C to 130 °C in technical and biological media, which are all but ideal aqueous solutions, require new approaches to pH monitoring. The glass electrode, introduced nearly hundred years ago, and chemical sensors based on field effect transistors (ISFET) show specific drawbacks with respect to handling and long-time stability...
متن کاملContinuous Monitoring of pH using Ion-selective Field Effect Transistors (ISFET’s) Operating with a Fixed Bias Applied to the Reference Electrode
A method for correction of threshold voltage drift in pH-sensitive ion-selective field effect transistors (ISFET’s) is presented. The proposed method allows accurate continuous monitoring of pH under clinical conditions corresponding to rapid pH changes such as those encountered in acute metabolic acidosis and cardiopulmonary bypass operations. This method, which involves monitoring the differe...
متن کاملReview on Graphene FET and its Application in Biosensing
Graphene, after its first production in 2004 have received lots of attentions from researchers because of its unique properties. High mobility, high sensitivity, high selectivity and high surface area make graphene excellent choice for bio application. One of promising graphene base device that has amazingly high sensitivity is graphene field-effect transistor (GFET). This review selectively su...
متن کاملReview on Graphene FET and its Application in Biosensing
Graphene, after its first production in 2004 have received lots of attentions from researchers because of its unique properties. High mobility, high sensitivity, high selectivity and high surface area make graphene excellent choice for bio application. One of promising graphene base device that has amazingly high sensitivity is graphene field-effect transistor (GFET). This review selectively su...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Gut
دوره 32 3 شماره
صفحات -
تاریخ انتشار 1991