Astigmatic mirror multipass absorption cells for long-path-length spectroscopy.

نویسندگان

  • J B McManus
  • P L Kebabian
  • M S Zahniser
چکیده

A multipass absorption cell, based on an astigmatic variant of the off-axis resonator (Herriott) configuration, has been designed to obtain long path lengths in small volumes. Rotation of the mirror axes is used to obtain an effective adjustability in the two mirror radii. This allows one to compensate for errors in mirror radii that are encountered in manufacture, thereby generating the desired reentrant patterns with less-precise mirrors. Acombination of mirror rotation and separation changes can be used to reach a variety of reentrant patterns and path lengths with a fixed set of astigmatic mirrors. The accessible patterns can be determined from trajectories, as a function of rotation and separation, through a general map of reentrant solutions. Desirable patterns for long-path spectroscopy can be chosen on the basis of path length, distance of the closest beam spot from the coupling hole, and tilt insensitivity. We describe the mathematics and analysis methods for the astigmatic cell with mirror rotation and then describe the design and test of prototype cells with this concept. Two cell designs are presented, a cell with 100-m path length in a volume of 3 L and a cell with 36-m path length in a volume of 0.3 L. Tests of low-volume absorption cells that use mirror rotation, designed for fast-flow atmospheric sampling, show the validity and the usefulness of the techniques that we have developed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple dense-pattern optical multipass cells.

Multiple-pass optical cells with dense spot patterns are useful for many applications, especially when the cell volume must be minimized relative to the optical path length. Present methods to achieve these dense patterns require expensive, highly precise astigmatic mirrors and complex alignment procedures. This work describes a new, simpler, and less demanding mirror system, comprising either ...

متن کامل

Quantum cascade laser-based multipass absorption system for hydrogen peroxide detection

Hydrogen peroxide (H2O2) is a relevant molecular trace gas species, that is related to the oxidative capacity of the atmosphere, the production of radical species such as OH, the generation of sulfate aerosol via oxidation of S(IV) to S(VI), and the formation of acid rain. The detection of atmospheric H2O2 involves specific challenges due to its high reactivity and low concentration (ppbv to su...

متن کامل

Multipass cell based on confocal mirrors for sensitive broadband laser spectroscopy in the near infrared.

We report on broadband absorption spectroscopy in the near IR using a multipass cell design based on highly reflecting mirrors in a confocal arrangement having the particular aim of achieving long optical paths. We demonstrate a path length of 314 m in a cell consisting of two sets of highly reflecting mirrors with identical focal length, spaced 0.5 m apart. The multipass cell covers this path ...

متن کامل

Low-volume, fast response-time hollow silica waveguide gas cells for mid-IR spectroscopy.

Hollow silica waveguides (HSWs) are used to produce long path length, low-volume gas cells, and are demonstrated with quantum cascade laser spectroscopy. Absorption measurements are made using the intrapulse technique, which allows measurements to be made across a single laser pulse. Simultaneous laser light and gas coupling is achieved through the modification of commercially available gas fit...

متن کامل

Optimum signal-to-noise ratio in off-axis integrated cavity output spectroscopy.

The signal-to-noise ratio (SNR) in off-axis integrated cavity output spectroscopy (OA-ICOS) is investigated and compared to direct absorption spectroscopy using multipass absorption cells [tunable diode laser absorption spectroscopy (TDLAS)]. Applying measured noise characteristics of a near-IR tunable diode laser and detector, it is shown that the optimum SNR is not generally reached at the hi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 34 18  شماره 

صفحات  -

تاریخ انتشار 1995