Observation of the embolus protection filter for Carotid Artery Stenting.
نویسندگان
چکیده
BACKGROUND Carotid artery stenting in patients with high surgical risk is considered as an effective alternative to carotid endarterectomy. Because the occurrence of distal embolization with CAS is still a major concern, an embolus protection device is usually used during the procedure. We developed a technique for observation of embolus protection filter and evaluated the debris or thrombus microscopically, and the pathologic findings were compared with preoperative imaging studies. METHODS After completing CAS, the filter membrane was stained with HE solution and removed from filter strut. Mounting onto a glass slide, the filter was evaluated under a microscope. Plaque debris and appearance of filter membrane were evaluated, and the covered area was measured. The pathologic findings were compared with preoperative imaging studies. RESULTS Microscopic observation of the slide revealed atheromatous debris as well as thrombotic material to the filter membrane. Hematoxylin-eosin stain facilitates the characterization of the debris composition, namely, thrombotic debris, calcified debris, organized debris, fibrous debris, and lipid-rich debris. The subtypes of debris were consistent with preoperative imaging studies. Thus, in cases of intraprocedural flow impairment, more than 50% of the filter area was covered with debris or thrombotic material. CONCLUSION Carotid plaque debris captured during carotid stenting with protection filter can be visualized with HE stain on the glass side. This simple method allows us to better understand the plaque debris and appearance of embolus protection filter.
منابع مشابه
ANGIOPLASTY AND STENTING OF CAROTID ARTERY STENOSIS WITH EMBOLIC PROTECTION DEVICES
Background: Carotid artery stenting (CAS) has recently been recommended as an alternative to carotid endarterectomy (CEA) by some clinicians. Objective: This study was designed to evaluate the success rate and in-hospital and 30-day adverse events in our first experiences in Iran for CAS with protection devices, to document our results and guide further use of CAS. Methods: From December 2...
متن کاملCaptured Macro-embolus of Fractured Atheromatous Plaque by the Embolic Protection Device during Carotid Stent Assisted Angioplasty
The authors present a case in which macro-embolus from the ruptured atheromatous plaque developed during carotid artery stenting (CAS). A 63-year-old man who had suffered a left middle cerebral artery territory infarction had significant proximal left internal carotid artery stenosis required CAS procedure. Immediate after stent deployment, the patient showed abrupt neurological deterioration w...
متن کاملCarotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion
Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...
متن کاملClinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting.
OBJECTIVE The main concern during transfemoral carotid artery stenting (CAS) is preventing cerebral embolus dislodgement. We compared clinical outcomes and intraprocedural embolization rates of CAS using a distal filter protection device or proximal balloon occlusion device. METHODS From January 2011 to March 2015, a series of 58 patients with symptomatic or asymptomatic internal carotid arte...
متن کاملRegarding "A randomized trial of carotid artery stenting with and without cerebral protection".
BACKGROUND The use of a distal filter cerebral protection device with carotid artery stenting is commonplace. There is little evidence, however, that filters are effective in preventing embolic lesions. This study examined the incidence of embolic phenomenon during carotid artery stenting with and without filter use. METHODS This was a prospective, randomized, single-center study of carotid a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Surgical neurology
دوره 72 5 شماره
صفحات -