Influence of polymer structure on electroosmotic flow and separation efficiency in successive multiple ionic layer coatings for microchip electrophoresis.

نویسندگان

  • Kanokporn Boonsong
  • Meghan M Caulum
  • Brian M Dressen
  • Orawon Chailapakul
  • Donald M Cropek
  • Charles S Henry
چکیده

The effect of successive multiple ionic layer (SMIL) coatings on the velocity and direction of EOF and the separation efficiency for PDMS electrophoresis microchips was studied using different polymer structures and deposition conditions. To date, the majority of SMIL studies have used traditional CE and fused-silica capillaries. EOF was measured as a function of polymer structure and number of layers, in one case using the same anionic polymer and varying the cationic polymer and in the second case using the same cationic polymer and varying the anionic polymer. In both situations, the EOF direction reversed with each additional deposited polymer layer. The absolute EOF magnitude, however, did not vary significantly with layer number or polymer structure. Next, different coatings were used to compare separation efficiencies on native and SMIL-coated PDMS microchips. For native PDMS microchips, the average separation efficiency was 4105 +/- 1540 theoretical plates. The addition of two layers of polymer increased the separation efficiency anywhere from two- to five-fold, depending on the polymer structure. A maximum separation efficiency of 12 880 +/- 1050 theoretical plates was achieved for SMIL coatings of polybrene (cationic) and dextran sulfate (anionic) polymers after deposition of six total layers. It was also noted that coating improved run-to-run consistency of the peaks as noted by a reduction of the RSD of the EOF and separation efficiency. This study shows that the use of polyelectrolyte coatings, irrespective of the polymer structure, generates a consistent EOF in the current experiments and dramatically improves the separation efficiency when compared to unmodified PDMS microchips.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pdms Microchip Electrophoresis with High Separation Efficiency by Simple and Quick Modification of Phospholipid Polymer

This paper reports the high separation efficiency zone-electrophoresis of proteins in poly(dimethylsiloxane) (PDMS) microchip coated with the physically adsorbed phospholipid polymer, poly(2-methacryloyloxyethyl phosphorylcholine (MPC)-co-3-(methacryloyloxy)propyltris(trimethylsiloxy)silane (MPTSSi)) (PMMSi), using the simple and quick dip coating method. High suppression of protein adsorption ...

متن کامل

Critical factors for high-performance physically adsorbed (dynamic) polymeric wall coatings for capillary electrophoresis of DNA.

Physically adsorbed (dynamic) polymeric wall coatings for microchannel electrophoresis have distinct advantages over covalently linked coatings. In order to determine the critical factors that control the formation of dynamic wall coatings, we have created a set of model polymers and copolymers based on N,N-dimethylacrylamide (DMA) and N,N-diethylacrylamide (DEA), and studied their adsorption b...

متن کامل

Improved CZE capabilities with new dynamic coatings.

Electroosmotic flow (EOF) is one of the fundamental processes affecting both resolution and separation times in capillary zone electrophoresis (CZE). EOF is a function of pH and buffer composition (zeta potential) in bare-silica capillaries at any pH above 3 and runs in the cathodal direction, decreasing the effective separation length for cationic species. On the other hand, the absence of EOF...

متن کامل

Polyelectrolyte-modified short microchannel for cation separation.

Three alkali cations, potassium, sodium, and lithium, have been separated within 15 s in a 1 cm long polymer microchip. The separation microchannel is modified by a polycation, poly(allylammonium chloride), which makes the channel surfaces positively charged leading to a reversed electroosmotic flow (EOF) when compared to bare channels. Due to the decreased apparent mobility of the cations, the...

متن کامل

A chip-based capillary electrophoresis-contactless conductivity microsystem for fast measurements of low-explosive ionic components.

A miniaturized analytical system for separating and detecting inorganic explosive residues, based on the coupling of a micromachined capillary electrophoresis (CE) chip with a contactless conductivity detector is described. The low electroosmotic flow (EOF) of the poly(methylmethacrylate) (PMMA) chip material facilitates the rapid switching between analyses of cations and anions using the same ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Electrophoresis

دوره 29 15  شماره 

صفحات  -

تاریخ انتشار 2008