Electro-mechanical modeling of Nb3Sn CICC performance degradation due to strand bending and inter-filament current transfer
نویسنده
چکیده
Please cite this article in press as: Zhai Y. Electr current transfer. Cryogenics (2009), doi:10.1016 Performance degradation of Nb3Sn cable-in-conduit conductors (CICCs) is a critical issue in large-scale magnet design such as the International Thermonuclear Experimental Reactor (ITER) and the seriesconnected hybrid (SCH) magnets currently under development at the National High Magnetic Field Laboratory (NHMFL). Not only the critical current is significantly lower than expectations but also the voltage–current characteristic is observed to have a much broader transition from a single strand to a CICC cable. The variation of conductor voltage–current characteristic as a result of cable electromagnetic, mechanical and thermal interactions is challenging to model. In this paper, we use a new numerical model, called the Florida electro-mechanical cable model (FEMCAM) benchmarked against 40 different conductor tests, to study the influence of bending strain and current non-uniformity on the critical current and n-value of Nb3Sn strands and CICC cables. The new model combines thermal bending effects during cool-down, electromagnetic bending effects during magnet operation and current transfer in strands with filament fracture. The n-value of a strand under bending is derived from integration of filament critical current over strand cross-section for full and no current transfer. The cable n-value is obtained from the power law relation of cable electric field and critical current curve. By comparing numerical results with measurements of advanced Nb3Sn strands and various CICC cables, we demonstrate that FEMCAM is self-consistent in modeling inter-filament current transfer. The new model predicts that Ic degradation of bent strands initially follows closely full current transfer but starts deviating and falls between full and no current transfer with an increasing bending strain. The results agree with recent TARSIS measurements for less than 1% bending strain mostly interested in practice. The strand n-value degradation from FEMCAM with no filament current transfer agrees better with measurements than that from full current transfer. Finally, FEMCAM simulated cable n-values are compared with various CICC measurements. The results imply that FEMCAM is a useful tool for the design of Nb3Sn-based CICCs and both thermal bending and electromagnetic bending play important roles in CICC performance. 2009 Elsevier Ltd. All rights reserved.
منابع مشابه
Florida electro-mechanical cable model of Nb3Sn CICCs for high-field magnet design
Performance degradation of Nb3Sn cable-in-conduit-conductors (CICCs) is a critical issue in large-scale magnet design such as in the International Thermonuclear Experimental Reactor (ITER) and the series-connected hybrid (SCH) magnets currently under development at the National High Magnetic Field Laboratory (NHMFL). The critical current Ic of Nb3Sn conductors is strongly affected by thermal pr...
متن کاملModeling of the Performance of Nb3Sn CICCs for High Field Magnet Design
Accurate prediction of the performance of Nb3Sn cable-in-conduit-conductors (CICCs) is challenging but critical for the design of high field magnets such as the series connected hybrid (SCH) magnet currently under development at the NHMFL. With various CICC tests performed for EFDA dipole magnet and ITER, we present the Florida electro-mechanical cable model (FEMCAM) and demonstrate that it is ...
متن کاملBending-Strain Test Results of ITER Nb3Sn Wires and Preliminary Model Analysis
Bending effects on Nb 3 Sn wires have been investigated to understand the critical current degradation of large Nb 3 Sn superconducting cables, such as the ITER conductors. Characterizations of the critical currents of various Nb 3 Sn wires were carried out by a previously reported pure-bending strand test device using the 20 T, 195 mm Bitter magnet at the National High Magnetic Field Laborator...
متن کاملThe Influence of Nb3Sn Strand Geometry on Filament Break- age under Bend Strain as Re- vealed by Metallography
The non-Cu critical current density of Nb3Sn strands has been pushed towards 3000 A/mm2 (12 T, 4.2 K) by increasing the Sn content and reducing the interfilamentary Cu. We compare the susceptibility to A15 filament breakage (under 0.5% bend strain) of the new high-Jc internal Sn conductor geometries with both high-Jc Powder-in-Tube (PIT) and low hysteresis loss distributed filament ITER designs...
متن کاملImage Analysis of Nb3Sn Strand For ITER Application: A comparison with SSC Nb-Ti
We have quantified the distribution of filament sizes and filament separation in internal Sn type Nb3Sn strand manufactured to ITER specification. In Nb-Ti strand for the SSC we had found a clear relationship between filament cross-sectional uniformity in a given cross-section and the n-value for an entire strand, but for the Nb3Sn we are not able to find one. In these Nb3Sn strands, however, t...
متن کامل