Intraobserver repeatability and interobserver reproducibility in musculoskeletal ultrasound imaging measurements.

نویسندگان

  • P V Balint
  • R D Sturrock
چکیده

OBJECTIVE To assess the repeatability and reproducibility of ultrasonographic measurements at the anterior surface of the femoral neck and iliofemoral ligament and on a human tissue-mimicking phantom. METHODS Two independent investigators studied 22 consecutive hips. One investigator had previous experience in musculoskeletal ultrasonography (US). The other investigator had undergone a short course in hip sonography (only 3 hours). Both investigators were blinded to their own and each other's results. On the phantom both observers had taken 10 vertical measurements at 6 cm deep where two objects were placed at 2 cm from each other. Calculation of measurement errors, percent errors and the Bland-Altman graphic technique were used for analysis of data. RESULTS After 132 examinations the first investigator's within-subject standard deviation was 0.4 mm. The intraobserver error was 4.75%. The second investigator's within-subject standard deviation was 0.6 mm and his intraobserver error was 7.00%. The interobserver error was 10.91%. After 20 phantom examinations the first investigators's intraobserver error was 1.11% and the second investigator's intraobserver error was 1.47%. CONCLUSION An inexperienced musculoskeletal sonographer can achieve an acceptable performance if given appropriate training.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraobserver and interobserver variability of ovarian volume, gray-scale and color flow indices obtained using transvaginal three-dimensional power Doppler ultrasonography.

OBJECTIVE To assess intraobserver and interobserver variability in ovarian volume and gray-scale and color flow index measurements using transvaginal, three-dimensional, power Doppler ultrasonography. METHODS Eleven women (22 ovaries) were examined on day 8 of controlled ovarian hyperstimulation therapy, which was part of their in vitro fertilization treatment protocol. The patients were exam...

متن کامل

Assessment of Technetium-99m Labeled Macroaggregated Albumin Rhinoscintigraphy for the Measurement of Nasal Mucociliary Transport Rate: Intratest, Interobserver, and Intraobserver Reproducibility

Objectives. The measurement of mucociliary transport velocity by rhinoscintigraphy with Tc-99m-macroaggregated albumin ((99m)Tc-MAA) is reliable measure of mucociliary clearance. The aim of this study is to assess the intratest, interobserver, and intraobserver reproducibility of nasal mucociliary transport rate (NMTR) measurement. Materials and Methods. Twenty-two subjects were evaluated to de...

متن کامل

Reproducibility of ultrasound measurement of the abdominal aorta.

BACKGROUND Abdominal aortic aneurysm (AAA) screening and surveillance programmes use ultrasound imaging to measure the anteroposterior (AP) diameter of the infrarenal aorta. The aim of this study was to examine potential observer bias and variability in ultrasound measurements. METHODS Studies were identified for review via a MEDLINE database search (1966-2009). References supplied in accesse...

متن کامل

Precision (Repeatability and Reproducibility) and Agreement of Corneal Power Measurements Obtained by Topcon KR-1W and iTrace

PURPOSE To evaluate the repeatability and reproducibility of corneal power measurements obtained by Topcon KR-1W and iTrace, and assess the agreement with measurements obtained by Allegro Topolyzer and IOLMaster. METHODS The right eyes of 100 normal subjects were prospectively scanned 3 times using all the 4 devices. Another observer performed additional 3 consecutive scans using the Topcon K...

متن کامل

Measurement of ultrasound biomicroscopy images: intraobserver and interobserver reliability.

PURPOSE To evaluate intraobserver and interobserver reproducibility of measurement of images obtained during ultrasound biomicroscopy. METHODS Four anterior segment images of four normal patients were obtained by a single examiner. The measurements of three independent observers were compared to assess interobserver reproducibility in quantifying the images. Thirteen different anterior segmen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical and experimental rheumatology

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2001