Digital Pressure Gauges with Alarms

ثبت نشده
چکیده

Accuracy Includes linearity, hysteresis, repeatability ±0.25% of full scale ±1 least significant digit Display 4 readings per second nominal display update rate 4 digit LCD, 0.5" H main display 5 character 0.25" H alphanumeric lower display Alarm 1 and Alarm 2 LCD indicators and bi-color (red/green) LEDs Controls & Functions SEL Select and display alarm trip points TEST Alarm acknowledge, or toggle alarms when in test mode  Increase alarm setpoint when in setpoint adjust mode  Decrease alarm setpoint when in setpoint adjust mode Multi-level pass code protection for set-up and calibration ADA and DAR Alarm Outputs Programmable dual form C (SPDT) relay contacts for HI/LO, HI/HI, LO/LO, normal or reverse acting with 1% deadband, or adjustable trip and reset points for each relay, manual or auto acknowledge. 1A/24VDC, 0.5A/115VAC, non-inductive 120 milliseconds typical response time DAR Retransmission Output Updated approximately 16 times per second 4-20 mA DC current output Output drive (compliance) determined by power source 6,553 counts (2.4 μA resolution) over sensor range Calibration Non-interactive, ±10% of range All pressure and absolute models: zero, midpoint, span All vacuum models: –span, –midpoint, zero Vacuum/pressure models: –span, zero, +midpoint, +span Power 8 to 24 VAC 50/60 Hz or 9 to 32 VDC Gauge is on whenever power is applied Designed for continuous operation 1.0 watt maximum power consumption Use DPG1000-PS 12 VDC power supply kit to operate on 115 VAC Weight Gauge: 10 ounces, shipping wt.: 1 pound (approximately) Housing Extruded aluminum case, epoxy powder coated, ABS/ polycarbonate bezel (aluminum bezel optional), front and rear gaskets, polycarbonate label Connection, Material, Media Compatibility 1/4" NPT male fitting, 316L stainless steel All wetted parts are 316L stainless steel Overpressure 2 X pressure range for 3 psi to 2000 psi sensors 5000 psig for ranges using 3000 psig sensor 7500 psig for ranges using 5000 psig sensor Over-range display 112.5% FS: I – – – or I –.–.–.– Vacuum service: all 15 psi, 30 psia, all 100 psi, all 200 psi sensors Under-range display (non-vacuum sensors): –Err Burst Pressure 4 X sensor pressure rating or 10,000 psi, whichever is less Environmental Storage temperature: –40 to 203°F (–40 to 95°C) Operating temperature: –4 to 185°F (–20 to 85°C) Compensated temperature: 32 to 158°F (0 to 70°C)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigations on Measurement Uncertainty and Stability of Pressure Dial Gauges and Transducers

Several commercial instruments are available for pressure measurements. As per ISO stipulations, whenever such instruments are used for precise and accurate pressure measurements, it is obligatory on the part of measurement authority to indicate the quality of results. Stability of the pressure measuring instruments over the years is one of the important parameters in defining the quality of re...

متن کامل

ررسی تجربی افت فشار جریان جوششی مبرد R-134a در لوله‌های افقی

The pressure drop of refrigerant R-134a flow boiling inside a horizontal tube has been investigated experimentally. The test set-up which was used in this investigation is a well instrumented vapor compression refrigeration system. These instruments are thermocouples, flow meter, pressure gauges and the pressure drop measuring apparatus. This system consisted of three electrically heated evapor...

متن کامل

XIX IMEKO World Congress

Vacuum technology is one of the established advanced technologies, of present age, in the field of research and industry. Having numerous applications, in the areas of human activities, one is concerned with a relatively large vacuum chamber where pressure distribution is, usually, not uniform during dynamic gas flow. To minimize the pressure non-uniformities in such chambers, baffles are gener...

متن کامل

Consider robust tank overfill prevention and independent alarm and gauging systems

Elimination of tank overfills is a significant problem for the petroleum industry. Since most tank receiving operations are manual, the operators rely heavily on tank level gauges and alarms for overfill prevention. Tracing the historical development of tank gauging and alarm systems provides insight into why independence is so important. This history is interwoven with interpretations, insight...

متن کامل

Accurate characteristics of Helium in nano-channels

This article describes an accurate subPico flowmeter bifurcatedin to liquid and gas flowrates less than 1mol/s for both MEMS/NEMS and cryogenic technology applications. The MEMS/NEMS are described as either two Gauges (instrument), or quartz fluctuating forks, even if the liquid or gas flows through an element, as well as cryogenic technology consisting of arrays of e...

متن کامل

A Gas Pressure Scale Based on Primary Standard Piston Gauges

The National Institute of Standards and Technology (NIST) has redefined its gas pressure scale, up to 17 MPa, based on two primary standard piston gauges. The primary standard piston gauges are 35.8 mm in diameter and operate from 20 kPa to 1 MPa. Ten secondary standard piston gauges, two each of five series of the Ruska 2465 type, with successively smaller diameters form the scale extending up...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013