Resting Aortic Valve Area at Normal Transaortic Flow Rate Reflects True Valve Area in Suspected Low-Gradient Severe Aortic Stenosis.

نویسندگان

  • Navtej S Chahal
  • Maria Drakopoulou
  • Ana M Gonzalez-Gonzalez
  • Ramasamy Manivarmane
  • Rajdeep Khattar
  • Roxy Senior
چکیده

OBJECTIVES This study sought to assess the diagnostic impact of stress echocardiography (SE) in patients with suspected low-flow, low-gradient aortic stenosis but normal resting transvalvular flow rate. BACKGROUND SE may help to distinguish between true severe aortic stenosis and pseudosevere aortic stenosis in patients with low aortic valve area (AVA) and mean gradient. However, if rest flow rate is normal, then SE may not confer any additional diagnostic value, irrespective of resting left ventricular ejection fraction (LVEF) and indexed stroke volume (SVi). METHODS Sixty-seven patients with suspected low-flow, low-gradient aortic stenosis who underwent SE were retrospectively studied. Following stratification by rest LVEF, SVi, and flow rate-using cutoffs of 50%, 35 ml/m(2), and 200 ml/s, respectively-we tested for significant changes in AVA during SE. RESULTS Mean age was 77 ± 9 years and 60% of patients were male. Mean values for rest variables were as follows: AVA: 0.77 ± 0.12 cm(2); mean gradient: 27 ± 7 mm Hg; flow rate: 182 ± 37 ml/s; SVi: 32 ± 8 ml/m(2); and LVEF: 45 ± 15%. During SE, significant increases in AVA were observed regardless of resting LVEF and SVi state. In patients with rest flow rate ≥200 ml/s, AVA did not increase significantly during stress (rest AVA: 0.90 cm(2) vs. stress AVA: 0.97 cm(2); p = 0.11), and positive predictive value for confirming underlying true severe aortic stenosis was 84%. In adjusted analyses, rest flow rate was the only parameter associated with severe AS (odds ratio: 1.05, 95% confidence interval: 1.0 to 1.1; p = 0.002). CONCLUSIONS Rest AVA measured under normal flow rate conditions is likely to reflect the true severity of AS and unlikely to change significantly with SE. Flow normalization may only be required in patients with AVA <1 cm(2) and mean gradient <40 mm Hg when the rest flow rate is <200 ml/s.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predictors of Outcomes in Low-Flow, Low-Gradient Aortic Stenosis

Background—Patients with low-flow, low-gradient aortic stenosis have a poor prognosis with conservative therapy but a high operative mortality if treated surgically. Recently, we proposed a new index of aortic stenosis severity derived from dobutamine stress echocardiography, the projected aortic valve area at a normal transvalvular flow rate, as superior to other conventional indices to differ...

متن کامل

Predictors of outcomes in low-flow, low-gradient aortic stenosis: results of the multicenter TOPAS Study.

BACKGROUND Patients with low-flow, low-gradient aortic stenosis have a poor prognosis with conservative therapy but a high operative mortality if treated surgically. Recently, we proposed a new index of aortic stenosis severity derived from dobutamine stress echocardiography, the projected aortic valve area at a normal transvalvular flow rate, as superior to other conventional indices to differ...

متن کامل

Effects of increasing flow rate on aortic stenotic indices: evidence from percutaneous transvenous balloon dilatation of the mitral valve in patients with combined aortic and mitral stenosis.

OBJECTIVES To investigate the effects of transvalvar flow rate on aortic valve resistance and valve area after percutaneous transvenous balloon dilatation of the mitral valve in a homogeneous group of patients with rheumatic heart disease. DESIGN Retrospective analysis of 12 patients with combined aortic and mitral stenosis who had undergone balloon dilatation of the mitral valve over a perio...

متن کامل

Stenotic Aortic Valve Area

I n aortic stenosis, the aortic valve area (AVA) is intuitively the most appealing measure of severity because it is supposed to be (largely) independent of stroke volume and left ventricular pump function and reflects most closely “stenosis.” Calculation of the AVA by the continuity equation is routinely performed in echocardiography (1), using 3 measurements: the velocity-time integral of the...

متن کامل

Valvuloarterial impedance, but not aortic stenosis severity, predicts syncope in patients with aortic stenosis.

BACKGROUND The presence of syncope in patients with aortic valve stenosis (AS) predicts a grave prognosis. However, the evaluation of AS severity has been limited to valve-specific factors such as aortic valve area and mean transaortic pressure gradient. Recently, valvuloarterial impedance (Zva) was proposed for the estimation of global left ventricular afterload. Therefore, because predictors ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 8 10  شماره 

صفحات  -

تاریخ انتشار 2015