A Remote Controlled Switching System with a Sequential Power ‘ON’ Attribute
نویسندگان
چکیده
Many essential appliances like air conditioners and refrigerators which run in our offices and homes draw a heavy starting current. When the main power resumes or turned ‘ON’ suddenly, all the loads are switched ‘ON’ at a time and a very heavy initial current is drawn from mains. The current drawn is so high that other equipments are affected. The valuable home appliances can be ruined for such an incident. Sometimes it causes short circuit effect and fire due to extensive heat. The switching system described in this paper switches ‘ON’ the loads sequentially with a steady time delay to avoid the limiting inrush current in this odd condition. Also we have shown a way to control the switching system by a remote control system. Finally, this kind of switching system can be an important tool to save the electrical home appliances from damage due to unwanted or irregular ON-OFF of the main power.
منابع مشابه
Reconfiguration and optimal placement of distributed generations in distribution networks in the presence of remote voltage controlled bus using exchange market algorithm
Abstract: Since distribution networks have a large share of the losses in power systems, reducing losses in these networks is one of the key issues in reducing the costs of global networks, including issues Which has always been considered. In this thesis, the reconfiguration of the distribution network in the presence of distributed generation sources (DGs) with respect to two types of bus, P ...
متن کاملA Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System
In recent years, there has been a fast growth in wind energy conversion system (WECS). There are two general types of wind turbines in WECS: fixed speed wind turbines and varying speed wind turbines.Permanent magnet synchronous generator (PMSG) is one of the most attractive generators for the varying speed turbine WECS.In this paper, a fuzzy controller is proposed to control the current source ...
متن کاملEstimation of New Weighted Controlled Switching Overvoltage by RBFN Model
Mitigating switching overvoltages (SOVs) and conducting well-suited insulation coordination for handling stresses are very important in UHV transmission Lines. The best strategy in the absence of arresters is controlled switching (CS). Although elaborate works on electromagnetic transients are considered in the process of designing transmission systems, such works are not prevalent in day-to-da...
متن کاملLow Power March Memory Test Algorithm for Static Random Access Memories (TECHNICAL NOTE)
Memories are most important building blocks in many digital systems. As the Integrated Circuits requirements are growing, the test circuitry must grow as well. There is a need for more efficient test techniques with low power and high speed. Many Memory Built in Self-Test techniques have been proposed to test memories. Compared with combinational and sequential circuits memory testing utilizes ...
متن کاملActive and Reactive Power Management of Wind Farm Based on a Six Leg Tow Stage Matrix Converter Controlled by a Predictive Direct Power Controller
In this paper we propose a new configuration of the wind farm connecting with an electrical grid. The proposed Wind Energy Conversion System (WECS) is based on a two stages six-leg matrix converter using to drive a two Doubly Fed Induction Machines operating at different wind speeds. Each Doubly Fed Induction Generator (DFIG) is controlled through the rotor currents using the Finite Set Model P...
متن کامل