Retinal oximetry with a scanning laser ophthalmoscope.

نویسندگان

  • Jona Valgerdur Kristjansdottir
  • Sveinn Hakon Hardarson
  • Gisli Hreinn Halldorsson
  • Robert A Karlsson
  • Thorunn S Eliasdottir
  • Einar Stefánsson
چکیده

PURPOSE The purpose of the study was to assess if a scanning laser ophthalmoscope (SLO), Optomap 200Tx, could be used for measurements of hemoglobin oxygen saturation in retinal blood vessels. METHODS Optomap 200Tx uses two lasers for image acquisition, 532 and 633 nm. Retinal images of healthy individuals and patients with retinal vein occlusion were analyzed with modified Oxymap Analyzer software, which tracks retinal vessels and calculates relative hemoglobin oxygen saturation. RESULTS Oxygen saturation in healthy individuals was measured as 92% ± 13% for arterioles and 57% ± 12% for venules (mean ± SD, n = 11, P = 0.0001). Standard deviation for repeated measurements of the same eye was 3.5% for arterioles and 4.4% for venules. In patients with confirmed venular hypoxia, central retinal vein occlusion (CRVO) or hemivein occlusion, the average venular oxygen saturation was measured as 23% ± 3% in the affected eyes and 59% ± 3% in the fellow eyes (n = 4, P = 0.0009). CONCLUSIONS Technically, it is possible to derive information on retinal oxygen saturation from an SLO with a 2-wavelength oximetry algorithm. The system produced both sensitive and repeatable results. The remaining challenges include decreasing variability between vessels of the same eye and variability between individuals. Given the advantages that SLO imaging has over conventional fundus camera optics in retinal oximetry, further development of SLO oximetry may provide the optimal approach to retinal oximetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal Oximetry with Scanning Laser Ophthalmoscope in Infants

PURPOSE Dual wavelength retinal oximetry has been developed for adults, but is not available for infants. Retinal oximetry may provide insight into the pathophysiology of oxygen-mediated diseases like retinopathy of prematurity. More insight in the oxygen metabolism of the retina in infants may provide valuable clues for better understanding and subsequent prevention or treatment of the disease...

متن کامل

Retinal Oximetry and Vessel Diameter Measurements With a Commercially Available Scanning Laser Ophthalmoscope in Diabetic Retinopathy

Purpose To test the hypothesis that retinal vascular diameter and hemoglobin oxygen saturation alterations, according to stages of diabetic retinopathy (DR), are discernible with a commercially available scanning laser ophthalmoscope (SLO). Methods One hundred eighty-one subjects with no diabetes (No DM), diabetes with no DR (No DR), nonproliferative DR (NPDR), or proliferative DR (PDR, all h...

متن کامل

Visual Acuity Measurement With a Second - Generation Scanning Laser Ophthalmoscope

Individuals with longstanding macular scotomas use an idiosyncratic, non-foveal retinal area adjacent to the scotoma to fixate and to inspect detailed visual stimuli (1). It is not known whether this preferred retinal locus (PRL) "selected" by the patient is the retinal area of highest residual visual acuity or how acuity is modified in retinal areas surrounding the scotoma. Because this inform...

متن کامل

Observation of cone and rod photoreceptors in normal subjects and patients using a new generation adaptive optics scanning laser ophthalmoscope

We demonstrate the capability of a new generation adaptive optics scanning laser ophthalmoscope (AOSLO) to resolve cones and rods in normal subjects, and confirm our findings by comparing cone and rod spacing with published histology measurements. Cone and rod spacing measurements are also performed on AOSLO images from two different diseased eyes, one affected by achromatopsia and the other by...

متن کامل

Adaptive optics scanning laser ophthalmoscope for stabilized retinal imaging.

A retinal imaging instrument that integrates adaptive optics (AO), scanning laser ophthalmoscopy (SLO), and retinal tracking components was built and tested. The system uses a Hartmann-Shack wave-front sensor (HS-WS) and MEMS-based deformable mirror (DM) for AO-correction of high-resolution, confocal SLO images. The system includes a wide-field line-scanning laser ophthalmoscope for easy orient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 55 5  شماره 

صفحات  -

تاریخ انتشار 2014