The role of cage height on the flexibility and load sharing of lumbar spine after lumbar interbody fusion with unilateral and bilateral instrumentation: a biomechanical study

نویسندگان

  • Lin Du
  • Xiao-jiang Sun
  • Tang-jun Zhou
  • Yuan-chao Li
  • Chen Chen
  • Chang-qing Zhao
  • Kai Zhang
  • Jie Zhao
چکیده

BACKGROUND One- and two-level lumbar interbody fusion with unilateral instrumentation is as effective as that with bilateral instrumentation. The height of the interbody cage influences the operated segment stability and the fusion technique success. The purpose of this research was to determine the effect of the fusion cage height (i.e. long and short) on both the stability (based on flexibility measures) and load sharing of the unilateral and bilateral instrumented transforaminal lumbar interbody fusion (TLIF) technique. METHODS The flexibility and load sharing tests were performed on seven human lumbar spines. Different configurations combining a long or short cage with a unilateral, bilateral, or no posterior fixation were used to stabilize the operated segment. Two sets of modular cages were designed for each type of test to simulate the long and short cages. During the flexibility test, a pure-moment load of 7.5 Nm was applied. The range of motion (ROM) was recorded for flexion-extension, lateral bending, and axial rotation. During the load sharing test, an axial-compression load of 400 N was applied. The load bearing of the cages was recorded using a cage-embedded load cell. RESULTS When the fusion cage height decreased 2 mm, the segment flexibility with unilateral fixation showed a significant increase in the ROM for flexion-extension, lateral bending, and axial rotation of 74.9, 83.8, and 175.2% (P < 0.01), respectively. In contrast, for bilateral fixation, the height decrease resulted in no significant change in ROM for flexion-extension (P = 0.686), lateral bending (P = 0.698), and axial rotation (P = 0.133). Using a short fusion cage, the load bearing decreased in 17.1, 21.5, and 54.1% (P < 0.05) for the cage alone, unilateral, and bilateral fixation, respectively. CONCLUSIONS A cage longer than the intervertebral space should be chosen to increase the stability and intervertebral graft load borne when performing TLIF with unilateral instrumentation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Is one cage enough in posterior lumbar interbody fusion: a comparison of unilateral single cage interbody fusion to bilateral cages.

Posterior lumbar interbody fusion (PLIF), as recommended with bilateral lumbar interbody cages and pedicle screw fixation, has increased the successful fusion rate to nearly 100%. Presently, a unilateral approach to the disc space with a variant of PLIF, the trans-foraminal interbody fusion is often used. There are few clinical studies of unilateral interbody fusion. The clinical and fusion res...

متن کامل

Biomechanics of lateral plate and pedicle screw constructs in lumbar spines instrumented at two levels with laterally placed interbody cages.

BACKGROUND CONTEXT The lateral transpsoas approach to interbody fusion is gaining popularity because of its minimally invasive nature and resultant indirect neurologic decompression. The acute biomechanical stability of the lateral approach to interbody fusion is dependent on the type of supplemental internal fixation used. The two-hole lateral plate (LP) has been approved for clinical use for ...

متن کامل

THE EFFECTS OF ANTERIOR DISCECTOMY AND INTERPOSITION AL IMPLANT UPON LUMBAR MOTION SEGMENT STABILITY

The cadaver spine motion segment behavior under torsional load was evaluated with the disc intact, with partial anterior discectomy and with spacer insertion. The results of this study explain how anterior lumbar discectomy and interbody fusion (ALIF) affects the torsional stability of the motion segment. The pseudarthrosis rate of the anterior lumbar discectomy and interbody fusion (ALIF)...

متن کامل

Role of Minimally Invasive Spine Surgery in Adults with Degenerative Lumbar Scoliosis: A Narrative Review

Background and Aim: Degenerative lumbar scoliosis is a spinal deformity resulting from advanced disc degeneration and facet arthropathy. Given the inconclusive available literature and lack of high-quality data supporting the role of minimally invasive surgical management of degenerative lumbar scoliosis, this review intends to highlight and compare the various viable minimally invasive surgica...

متن کامل

Biomechanical evaluation of an expandable cage in single-segment posterior lumbar interbody fusion.

STUDY DESIGN Controlled laboratory study. OBJECTIVE To evaluate the biomechanical characteristics of a new expandable interbody cage in single-segment posterior lumbar interbody fusion (PLIF) using cadaveric lumbar spines. SUMMARY OF BACKGROUND DATA One of the popular methods of treating lumbar spine pathologies involves a posterior lumbar interbody fusion using bilateral interbody nonexpan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017