Influence of Femoral Implant Alignment in Uncemented Total Hip Replacement Arthroplasty: Varus Insertion and Stress Shielding.

نویسندگان

  • Hidemi Kawaji
  • Takuya Uematsu
  • Ryosuke Oba
  • Naoya Hoshikawa
  • Hiroshi Watanabe
  • Shinro Takai
چکیده

BACKGROUND The influence of varus insertion of femoral implants in uncemented total hip replacement arthroplasty (THR) remains unclear. Thus, in this study, we retrospectively assessed the clinical impact of uncemented THR with femoral implants that were inserted in varus on the basis of radiological findings. MATERIALS AND METHODS The study participants included 89 patients who underwent uncemented THR for 106 joints and were followed-up for >3 years. From clinical records, we retrieved Japanese Orthopaedic Association (JOA) pain scores and the range of motion (ROM) of flexion and abduction both preoperatively and at the final follow-up. The presence of varus insertion of the femoral implant and stress shielding were also retrospectively reviewed from X-rays. We defined varus insertion of the femoral implant as the axis of the femoral implant that was inclined to the femoral shaft by 2° or more. Stress shielding was judged in accordance with Engh's classification system. RESULTS Of the 106 joints, varus insertion was observed in 40 (37.3%) (the varus group) but not in 66 (62.3%) (the non-varus group). The JOA pain score significantly improved in both groups; however, there were no significant differences between the groups. Although ROM improved in both groups, there were no significant differences between the groups. The appearance rate of stress shielding of ≥third degree in the varus group was significantly greater than that in the non-varus group. CONCLUSION These results revealed that varus insertion of femoral implants had no influence on short- to mid-term clinical outcomes because the pain score and ROM significantly improved in both the varus and non-varus groups. However, high rates of severe stress shielding appeared with varus insertion of femoral implants, suggesting an influence on long-term clinical outcomes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of cementless femoral stems inserted in varus on functional outcome in primary total hip arthroplasty.

INTRODUCTION Historically, cemented total hip arthroplasty (THA) femoral stems inserted in varus have yielded poor clinical results. Few studies to date have addressed the question of the effects of varus alignment on cementless stems. We conducted a retrospective review of 125 uncemented THA femoral stems implanted by a single surgeon from 1994 to 1999. METHODS We conducted a retrospective r...

متن کامل

Mid-Term Clinical Results of VerSys Hip System (Zimmer) Uncemented Total Hip Replacement Arthroplasty.

Recent reports suggest that uncemented total hip replacement arthroplasty (THR) results in favorable short- to mid-term clinical results. In the present study, we assessed the mid-term clinical results of VerSys Hip System uncemented THR at our hospital. MATERIALS AND METHODS We studied patients who received THR using VerSys Hip System and who could be followed-up more than 3 years. Clinical ...

متن کامل

The effects of necrotic lesion size and orientation of the femoral component on stress alterations in the proximal femur in hip resurfacing - a finite element simulation

BACKGROUND Due to the advantages of its bone-conserving nature, hip resurface arthroplasty (HRA) has recently gained the interest of orthopedic surgeons for the treatment of young and active patients who have osteonerosis of the femoral head. However, in long-term follow-up studies after HRA, narrowing of the femoral neck has often been found, which may lead to fracture. This phenomenon has bee...

متن کامل

Stress Fracture of the Lateral Femoral Condyle afterTotal Knee Arthroplasty

Background: This is to assess one of the rare complications after total knee replacement and to assess risk factors of failure.Methods: 11 patients with varus knee and an average age of 67 years underwent TKA between 2005 and 2013. All patients returned with a sudden sharp knee pain, disability to walk and significant decrease in ROM about 4 to 8 weeks after surgery. Radiographic examination re...

متن کامل

Stubby stems: good things come in small packages.

Standard-length porous-coated tapered femoral stems perform exceedingly well in primary total hip arthroplasty (THA) at long-term follow-up. Nevertheless, there are multiple reasons to strongly consider the relatively new concept of short tapered stems. First, there is already a wide variation in the lengths of "standard" components and the ideal length is unknown. The goal of tapered stems is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of Nippon Medical School = Nippon Ika Daigaku zasshi

دوره 83 6  شماره 

صفحات  -

تاریخ انتشار 2016