Prospective, randomized comparison of gadopentetate and gadobutrol to assess chronic myocardial infarction applying cardiovascular magnetic resonance

نویسندگان

  • Andre Rudolph
  • Daniel Messroghli
  • Florian von Knobelsdorff-Brenkenhoff
  • Julius Traber
  • Johannes Schüler
  • Ralf Wassmuth
  • Jeanette Schulz-Menger
چکیده

BACKGROUND We hypothesized that the contrast medium gadobutrol is not inferior compared to Gd-DTPA in identifying and quantifying ischemic late gadolinium enhancement (LGE), even by using a lower dose. METHODS We prospectively enrolled 30 patients with chronic myocardial infarction as visualized by LGE during clinical routine scan at 1.5 T with 0.20 mmol/kg Gd-DTPA. Participants were randomized to either 0.15 mmol/kg gadobutrol (group A) or 0.10 mmol/kg gadobutrol (group B). CMR protocol was identical in both exams. LGE was quantified using a semiautomatic approach. Signal intensities of scar, remote myocardium, blood and air were measured. Signal to noise (SNR) and contrast to noise ratios (CNR) were calculated. RESULTS Signal intensities were not different between Gd-DTPA and gadobutrol in group A, whereas significant differences were detected in group B. SNR of injured myocardium (53.5+/-21.4 vs. 30.1+/-10.4, p = 0.0001) and CNR between injured and remote myocardium (50.3+/-20.3 vs. 27.3+/-9.3, p < 0.0001) were lower in gadobutrol. Infarct size was lower in both gadobutrol groups compared to Gd-DTPA (group A: 16.8+/-10.2 g vs. 12.8+/-6.8 g, p = 0.03; group B: 18.6+/-12.0 g vs. 14.0+/-9.9 g, p = 0.0016). CONCLUSIONS Taking application of 0.2 mmol/kg Gd-DTPA as the reference, the delineation of infarct scar was similar with 0.15 mmol/kg gadobutrol, whereas the use 0.10 mmol/kg gadobutrol led to reduced tissue contrast. TRIAL REGISTRATION The study had been registered under EudraCT Number: 2010-020775-22. Registration date: 2010.08.10.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial Infarct Size by CMR in Clinical Cardioprotection Studies

OBJECTIVES The aim of this study was to review randomized controlled trials (RCTs) using cardiac magnetic resonance (CMR) to assess myocardial infarct (MI) size in reperfused patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND There is limited guidance on the use of CMR in clinical cardioprotection RCTs in patients with STEMI treated by primary percutaneous coronary i...

متن کامل

Single-Dose Gadobutrol in Comparison With Single-Dose Gadobenate Dimeglumine for Magnetic Resonance Imaging of Chronic Myocardial Infarction at 3 T

OBJECTIVES The aim of this study was to compare the contrast-to-noise ratio (CNR) values of infarct and remote myocardium as well as infarct and blood after application of 0.1 mmol/kg gadobutrol and 0.1 mmol/kg gadobenate dimeglumine on late gadolinium enhancement magnetic resonance (MR) images. MATERIAL AND METHODS The study was a prospective randomized controlled clinical study. After infor...

متن کامل

Relationship between Late Gadolinium Enhancement Extent in Cardiac Magnetic Resonance Imaging and Severity of Coronary Artery Disease in Old Myocardial Infarction

Purpose: To assess the relationship between the severity of coronary arteries involvement and the extent and pattern of myocardial scars in Cardiac Magnetic Resonance of patients with history of remote myocardial infarction. Materials and Methods: The Cardiac Magnetic Resonance images of sixty patients with history of remote ST segment or non-ST segment elevation myocardial infarction were ...

متن کامل

Comparison between a linear versus a macrocyclic contrast agent for whole body MR angiography in a clinical routine setting

BACKGROUND Previous experiences of whole body MR angiography are predominantly available in linear 0.5 M gadolinium-containing contrast agents. The aim of this study was to compare image quality on a four-point scale (range 1-4) and diagnostic accuracy of a 1.0 M macrocyclic contrast agent (gadobutrol, n = 80 patients) with a 0.5 M linear contrast agent (gadopentetate dimeglumine, n = 85 patien...

متن کامل

Efficacy and Safety of Gadobutrol (1.0 M) versus Gadopentetate Dimeglumine (0.5 M) for Enhanced MRI of CNS Lesions: A Phase III, Multicenter, Single-Blind, Randomized Study in Chinese Patients

The aim of this study was to compare the efficacy and safety of macrocyclic gadobutrol (1.0 M) with linear gadopentetate dimeglumine (0.5 M) for contrast-enhanced magnetic resonance imaging (MRI) of central nervous system (CNS) lesions in Chinese patients (N = 147) with known or suspected CNS lesions, who were enrolled in this single-blind, randomized, parallel-group study. Three blinded indepe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC medical imaging

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015