Fabrication of fritless chromatographic microchips packed with conventional reversed-phase silica particles.
نویسندگان
چکیده
This paper describes the development and study of a disposable and inexpensive microfluidic chip, fabricated from poly(dimethylsiloxane) (PDMS) incorporating conventional chromatographic reversed-phase silica particles (C18) without the use of frits, permanent physical barriers, tapers, or restrictors. The packing of C18 modified silica particles into the microfluidic channels is made possible by the hydrophobic nature and excellent elasticity of PDMS. Keystone-, clamping-, and anchor-effects provide the stability and the compactness of the packing and attenuated wall-effects were observed.
منابع مشابه
Electrochromatography in microchips packed with conventional reversed-phase silica particles.
This paper shows the applicability of a disposable and inexpensive microfluidic chip for electrochromatographic separations. The chip, recently developed by us for chip-based LC, was fabricated from PDMS incorporating conventional chromatographic RP silica particles (C18) without the use of frits. Three cephalosporin antibiotics were used to demonstrate the applicability of the chip-based chrom...
متن کاملA simple procedure for the preparation of fritless columns by entrapping conventional high performance liquid chromatography sorbents.
A rapid and direct method for immobilizing conventional high performance liquid chromatography (HPLC) packing material inside fritless capillaries has been developed. Due to the simple composition of the entrapment matrix (tetraethoxysilane, alkyltriethoxysilane, ethanol and water), straightforward manufacturing procedure and modest equipment requirement, the method can readily be transferred t...
متن کاملFritless capillary columns for HPLC and CEC prepared by immobilizing the stationary phase in an organic polymer matrix
A new design of immobilized particle separation media for capillary liquid chromatography and electrochromatography has been developed. A mixture of porogenic solvents and methacrylate-based monomers is pumped through a packed column to provide, following a polymerization step, an organic matrix capable of holding the sorbent particles in place, thus rendering the end frits unnecessary. The new...
متن کاملEnantiomer separation by capillary electrochromatography using fritless packed columns.
This review summarizes recent developments in the field of enantiomer separation by capillary electrochromatography using fritless packed columns. Various enantiomers have been separated by employing fritless packed columns prepared in a fused silica capillary either by the immobilization of chiral packing materials by sintering or sol-gel technology or by in situ polymerization of a mixture co...
متن کاملSurface diffusion in C(18)-silica monolithic stationary phase.
A peak parking-moment analysis method was used for the measurement of surface diffusion coefficient (D(s)) in a reversed-phase liquid chromatography (RPLC) system consisting of a C(18)-silica monolithic column and a mixture of methanol and water (70/30, v/v). The D(s) values experimentally measured were analyzed by considering the correlation with corresponding values of molecular diffusivity (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 79 20 شماره
صفحات -
تاریخ انتشار 2007