Granulomatous Lung Disease: A Novel Complication following Metallosis from Hip Arthroplasty

نویسندگان

  • Theodoros Balbouzis
  • Thomas Georgiadis
  • Peter Grigoris
چکیده

A case of a female patient with local and systemic complications of metallosis, following catastrophic wear of a revised hip arthroplasty, is presented. The patient had a history of a fractured ceramic-on-ceramic implant, exchanged with a metal-on-polyethylene prosthesis. Systemic complications included sarcoidosis-like reactions, presenting as granulomatous lung disease, along with chorioretinitis, erythema nodosum, and cardiomyopathy. High local and circulating cobalt and chromium levels established the diagnosis. The patient underwent extensive debridement and implant revision. One year postoperatively, she had no respiratory symptoms or functional impairment. Local and systemic complications of metallosis after hip arthroplasty should be promptly recognized and treated operatively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Delayed diagnosis of catastrophic ceramic liner failure with resultant pelvic discontinuity and massive metallosis

With newer-generation ceramic components used in total hip arthroplasty, component fracture is a rare complication. However rare, when ceramic component fracture does occur, prompt identification and revision is necessary as delay can lead to dramatic failure with resultant metallosis as the extremely hard ceramic debris abrades remaining components. We present a case of a 70-year-old woman wit...

متن کامل

The Result of Revision Total Hip Arthroplasty in Patients with Metallosis Following a Catastrophic Failure of a Polyethylene Liner

BACKGROUND Wear cannot be completely prevented after total hip arthroplasty. If severe polyethylene (PE) liner wear develops, the so-called catastrophic failure occurs and metallosis develops. We postulated that longevity of the new implant may be affected after revision surgery for metallosis following a catastrophic failure of a PE liner due to the substantial amount of PE wear particles and ...

متن کامل

Severe metallosis leading to femoral head perforation.

This article describes a case of severe metallosis in a 67-year-old woman who initially underwent primary total hip arthroplasty with a ceramic-on-ceramic articular bearing. This was subsequently revised to a metal-on-polyethylene articulation due to ceramic liner fracture. She presented with severe hip pain and a pelvic mass. Infective workup was negative. Perforation of the cobalt-chrome femo...

متن کامل

Metallosis-induced iliopsoas bursal cyst causing venous obstruction and lower-limb swelling after metal-on-metal THA.

The formation of iliopsoas bursal cystic lesions after total hip arthroplasty is an infrequently reported condition. This article describes an unusual complication of a current-generation metal-on-metal total hip arthroplasty.A woman presented with unilateral spontaneous lower-limb swelling that developed 5 years postoperatively. It occurred secondary to venous obstruction by a metallosis-induc...

متن کامل

Adverse reaction to metal debris: metallosis of the resurfaced hip

The greatest concern after metal-on-metal hip resurfacing may be the development of metallosis. Metallosis is an adverse tissue reaction to the metal debris generated by the prosthesis and can be seen with implants and joint prostheses. The reasons patients develop metallosis are multifactorial, involving patient, surgical, and implant factors. Contributing factors may include component malposi...