Use of chiral derivatization for the determination of dichlorprop in tea samples by ultra performance LC with fluorescence detection.
نویسندگان
چکیده
Dichlorprop is available for agricultural use as a chiral pesticide. In this study, the stereoselective determination of dichlorprop enantiomers in tea samples such as green, black, jasmine, and oolong was developed by ultra performance LC with fluorescence spectrometry after covalent chiral derivatization. The separation was achieved on an Acquity BEH C18 column with the mobile phase consisting of 0.1% formic acid in acetonitrile/water at a flow rate of 0.4 mL/min. In the covalent chiral derivatization using (S)-(+)-4-(N,N-dimethylaminosulfonyl)-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole, the peak resolution between the S and R-dichlorprop enantiomers was 2.6. LODs and LOQs values were 10 and 50 ng/mL standard solution. The linearity of the calibration curves yielded the coefficients (r(2) > 0.99, ranging from 0.05 to 5 μg/mL) of determination of each of the dichlorprop enantiomers. SPE extraction was used for the sample preparation of dichlorprop in various tea samples. Recoveries were in the range of 82.4-97.6% with associated precision values (within-day: 82.4-95.8%, n = 6, and between-day: 83.7-97.6% for 3 days) for repeatability and reproducibility. Based on this result, our method has been proven to be highly efficient and suitable for the routine assay of dichlorprop enantiomers in various tea samples. We propose that the ultra performance LC assay after covalent chiral derivatization would be the renewed tools in the era of chiral stationary platform for chiral pesticide residues in foods.
منابع مشابه
High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملHigh Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat
Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...
متن کاملStereospecific Determination of Mefloquine in Whole Blood by HPLC
Mefloquine, as a racemic mixture, is used for the treatment and prophylaxis of malaria. Stereoselective pharmacodynamic and pharmacokinetic differences has been observed for mefloquine. In this study a modified stereoselective HPLC method is presented for determination of mefloquine (MFQ) enantiomers in whole blood. The assay involved liquid-liquid extraction of MFQ from biological fluids with ...
متن کاملDetermination of ultra trace amount manganese (II) in water samples with the 1-(2-PyridylAzo)-2-Naphthol, (PAN) by the bromate ion in sulfuric acid with kinetic spectrophotometric method
A new kinetic spectrophotometic method for the determination of trace amount manganese(II) in Tea real samples has been described based on it s the catalytic effect on the oxidations of 1 - (2 – Pyridyl Azo) - 2 - Naphthol, (PAN), by potassium bromated in sulfuric acid. The reaction is followed spectrophotometrically by measuring the decrease in the absorbance at 547.5 nm. Under the optimum con...
متن کاملAnalysis of trace atrazine and simazine in environmental samples by liquid chromatography-fluorescence detection with pre-column derivatization reaction.
Coupled with off-line extraction, a pre-column derivatization liquid chromatographic fluorescence detection (LC-FL) procedure was developed for the determination of atrazine and simazine in soil, crop and water samples. Concentrations in real samples were expected to be at or below the low ng/g level, which requires pre-concentration of analytes and improved detection. 4-(2-Phthalimidyl) benzoy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of separation science
دوره 36 8 شماره
صفحات -
تاریخ انتشار 2013