Aging Index using Photoplethysmography for a Healthcare Device: Comparison with Brachial-Ankle Pulse Wave Velocity

نویسندگان

  • Kyung Soon Hong
  • Kyu Tae Park
  • Jae Mok Ahn
چکیده

OBJECTIVES Recent studies have emphasized the potential information embedded in peripheral fingertip photoplethysmogram (PPG) signals for the assessment of arterial wall stiffening during aging. For the discrimination of arterial stiffness with age, the brachial-ankle pulse wave velocity (baPWV) has been widely used in clinical applications. The second derivative of the PPG (acceleration photoplethysmogram [APG]) has been reported to correlate with the presence of atherosclerotic disorders. In this study, we investigated the association among age, the baPWV, and the APG and found a new aging index reflecting arterial stiffness for a healthcare device. METHODS The APG and the baPWV were simultaneously applied to assess the accuracy of the APG in measuring arterial stiffness in association with age. A preamplifier and motion artifact removal algorithm were newly developed to obtain a high quality PPG signal. In total, 168 subjects with a mean ± SD age of 58.1 ± 12.6 years were followed for two months to obtain a set of complete data using baPWV and APG analysis. RESULTS The baPWV and the B ratio of the APG indices were correlated significantly with age (r = 0.6685, p < 0.0001 and r = -0.4025, p < 0.0001, respectively). A regression analysis revealed that the c and d peaks were independent of age (r = -0.3553, p < 0.0001 and r = -0.3191, p < 0.0001, respectively). CONCLUSIONS We determined the B ratio, which represents an improved aging index and suggest that the APG may provide qualitatively similar information for arterial stiffness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study in the Use of Brachial Photoplethysmography and the Qrs Complex as Timing References in Determination of Pulse Transit Time

For more than a century, there has been interest in pulse wave velocity and pulse transit time as a possible metric for blood pressure and other cardiovascular parameters. The most common approach in noninvasive measurement of these metrics has been to measure the time delay between the QRS complex on the electrocardiograph and the detection of the finger photoplethysmograph. This paper introdu...

متن کامل

Brachial-ankle pulse wave velocity and symptomatic cerebral infarction in patients with type 2 diabetes: a cross-sectional study

BACKGROUND Recently a new automatic device that measures brachial-ankle pulse wave velocity using an oscillometric method has been developed. However, the practical significance of brachial-ankle pulse wave velocity measurement remains uncertain. The purpose of this study was to examine the association between brachial-ankle pulse wave velocity and symptomatic cerebral infarction in patients wi...

متن کامل

Influence of detraining on temporal changes in arterial stiffness in endurance athletes: a prospective study

[Purpose] We examined the effects of detraining on temporal changes in arterial stiffness in endurance athletes. [Subjects] Eighteen female university athletes requiring high endurance exercise capabilities were classified into 2 groups: 10 retired players (detraining group) and 8 active players (training group). [Methods] Brachial-ankle pulse wave velocity, an index of arterial stiffness, was ...

متن کامل

Validity and reproducibility of arterial pulse wave velocity measurement using new device with oscillometric technique: A pilot study

BACKGROUND Availability of a range of techniques and devices allow measurement of many variables related to the stiffness of large or medium sized arteries. There is good evidence that, pulse wave velocity is a relatively simple measurement and is a good indicator of changes in arterial properties. The pulse wave velocity calculated from pulse wave recording by other methods like doppler or ton...

متن کامل

Pulse wave velocity and digital volume pulse as indirect estimators of blood pressure: pilot study on healthy volunteers.

The purpose of the study was to asses the potential use of pulse wave velocity (PWV) and digital volume pulse (DVP) as estimators of systolic (SBP) and diastolic (DPB) blood pressure. Single and multiple correlation studies were conducted, including biometric parameters and risk factors. Brachial-ankle PWV (baPWV) and DVP signals were obtained from a Pulse Trace PWV and Pulse Trace PCA (pulse c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2015