Poor clinical performance of the Wessex porcine heart valve bioprosthesis at nine years' follow up.

نویسندگان

  • A Hurlé
  • J F Nistal
  • J M Revuelta
چکیده

OBJECTIVE To assess the long term performance of the Wessex porcine bioprostheses implanted in a consecutive series of patients. DESIGN A retrospective case series. PATIENTS Between January 1985 and July 1991, 184 Wessex bioprostheses (78 mitral, 102 aortic, and 4 tricuspid) were implanted in 150 patients. The patients were 55% (83/150) male and 45% (67/150) female; mean age was 60 (SD 10) years. RESULTS Hospital mortality was 9.3% (14/150). Total follow up was 696 patient-years (mean 4.7 years per patient). Linearised rates (events per 100 patient-years (SEM) for postoperative complications for patients with isolated mitral valve replacement, isolated aortic valve replacement, and multiple valve replacement were, respectively: late mortality: 4.7 (1.6), 3.3 (0.9), and 4.9 (1.9); thromboembolism: 5.8 (1.8), 3.0 (0.9), and 2.8 (1.4); valve thrombosis: 1.0 (0.7), 0.3 (0.3), and 0.7 (0.7); structural failure: 5.8 (1.7), 1.9 (0.7), and 7.1 (2.2). Actuarial freedom from complications at nine years (70% confidence interval) was: late mortality: 61 (9)%, 57 (13)%, and 59 (12)%; thromboembolism and valve thrombosis: 71 (9)%, 79 (6)%, and 81 (8)%; structural failure: 33 (14)%, 50 (16)%, and 12 (14)%; all valve related morbidity/mortality: 31 (10)%, 21 (11)%, and 7 (9)%. Stent fractures appeared in 11 of 17 explanted prostheses; actuarial freedom from stent fracture at nine years was 66 (12)%. CONCLUSIONS The Wessex bioprosthesis is associated with high thrombogenicity, early structural dysfunction, and a high valve related morbidity/mortality which justifies very close follow up of patients fitted with them.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive assessment by Doppler ultrasound of 155 patients with bioprosthetic valves: a comparison of the Wessex porcine, low profile Ionescu-Shiley, and Hancock pericardial bioprostheses.

One hundred and fifty five patients with 167 bioprosthetic valves (68 Wessex porcine, 54 Hancock pericardial, and 45 low profile Ionescu-Shiley pericardial valves) were studied by Doppler ultrasound. Valve gradients were calculated from the mitral and aortic flow velocities by the modified Bernoulli equation. Mean mitral gradients were significantly smaller across the Ionescu-Shiley valves than...

متن کامل

Mitral prosthetic valve regurgitation due to stent fracture of a porcine bioprosthesis.

Mitral prosthetic valve regurgitation due to stent fracture with consequent cusp prolapse occurred in two patients with a Wessex porcine bioprosthesis.

متن کامل

Durability of pericardial versus porcine aortic valves.

OBJECTIVES This study compares the long-term performance of the Carpentier-Edwards (CE) porcine bioprosthesis and the CE pericardial bioprosthesis for aortic valve replacement (AVR). BACKGROUND With new bioprostheses on the horizon, there is renewed interest in how the long-term durability of current pericardial bioprostheses compares with the traditional porcine bioprosthesis. METHODS We r...

متن کامل

The Edinburgh heart valve study.

Durability has always been a crucial performance indicator for artificial heart valves. There is the intrinsic durability of the valve itself, as constructed by the manufacturer, but it is the durability of the implanted valve in the individual patient which is the real issue, particularly, but not solely, for the patient. Progress in the design and manufacture of artificial heart valves has ar...

متن کامل

[Aortic valve replacement with a Cryolife O'Brien stentless bioprosthesis].

INTRODUCTION AND OBJECTIVES The Cryolife O'Brien xenograft is a stentless bioprosthesis constructed from noncoronary leaflets from three porcine aortic valves. The aim of this study was to investigate short-term results after aortic valve replacement with this composite xenograft. METHODS Since October 1993, Cryolife O'Brien bioprostheses have been implanted in 210 patients. The patients' mea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 77 4  شماره 

صفحات  -

تاریخ انتشار 1997