Breast Composition Measurements Using Retrospective Standard Mammogram Form (SMF)

نویسندگان

  • Ralph Highnam
  • Xiabo Pan
  • Ruth Warren
  • Mona Jeffreys
  • George Davey Smith
  • Michael Brady
چکیده

The standard mammogram form (SMF) representation of an x-ray mammogram is a standardized, quantitative representation of the breast from which the volume of non-fat tissue and breast density can be easily estimated, both of which are of significant interest in determining breast cancer risk. Previous theoretical analysis of SMF had suggested that a complete and substantial set of calibration data (such as mAs and kVp) would be needed to generate realistic breast composition measures and yet there are many interesting trials that have retrospectively collected images with no calibration data. The main contribution of this paper is to revisit our previous theoretical analysis of SMF with respect to errors in the calibration data and to show how and why that theoretical analysis did not match the results from the practical implementations of SMF. In particular, we show how by estimating breast thickness for every image we are, effectively, compensating for any errors in the calibration data. To illustrate our findings, the current implementation of SMF (version 2.2beta) was run over 4028 digitized film-screen mammograms taken from six sites over the years 1988-2002 with and without using the known calibration data. Results show that the SMF implementation running without any calibration data at all generates results which display a strong relationship with when running with a complete set of calibration data, and, most importantly, to an expert's visual assessment of breast composition using established techniques. SMF shows considerable promise in being of major use in large epidemiological studies related to breast cancer which require the automated analysis of large numbers of films from many years previously where little or no calibration data is available.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Classification of Mammogram Patterns using area measurements and the Standard Mammogram Form (SMF)

Our aim is to propose a new approach to breast pattern classification that will aid in the development of an automated mammographic density analysis procedure. Breast patterns broadly classify the mammographic density and density distribution of each mammogram in order to provide a framework for assessing the risk of breast cancer according to density. However, basic weaknesses of classifying m...

متن کامل

Screen-film mammographic density and breast cancer risk: a comparison of the volumetric standard mammogram form and the interactive threshold measurement methods.

BACKGROUND Mammographic density is a strong risk factor for breast cancer, usually measured by an area-based threshold method that dichotomizes the breast area on a mammogram into dense and nondense regions. Volumetric methods of breast density measurement, such as the fully automated standard mammogram form (SMF) method that estimates the volume of dense and total breast tissue, may provide a ...

متن کامل

Evaluating the effectiveness of using standard mammogram form to predict breast cancer risk: case-control study.

Breast density is a well-known breast cancer risk factor. Most current methods of measuring breast density are area based and subjective. Standard mammogram form (SMF) is a computer program using a volumetric approach to estimate the percent density in the breast. The aim of this study is to evaluate the current implementation of SMF as a predictor of breast cancer risk by comparing it with oth...

متن کامل

Comparison of a new and existing method of mammographic density measurement: intramethod reliability and associations with known risk factors.

BACKGROUND Mammographic density is one of the strongest risk factors for breast cancer. It is commonly measured by an interactive threshold method that does not fully use information contained in a mammogram. An alternative fully automated standard mammogram form (SMF) method measures density using a volumetric approach. METHODS We examined between-breast and between-view agreement, reliabili...

متن کامل

Detection of Microcalcifications using SMF

We have reported previously [10,6] two algorithms for detecting microcalcifications that operate either on Highnam and Brady’s [3] hint representation or the latter’s presentation as an image: SMF = Standardised Mammogram Form. We introduce a third such method that applies to SMF a model of human foveal image processing. Comparative analysis with [10,6] shows significantly enhanced results for ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 51 11  شماره 

صفحات  -

تاریخ انتشار 2006