Clinical usefulness of ECG-gated 18F-FDG PET combined with 99mTC-MIBI gated SPECT for evaluating myocardial viability and function.

نویسندگان

  • Yohei Yamakawa
  • Nobukazu Takahashi
  • Toshiyuki Ishikawa
  • Kazuaki Uchino
  • Yasuyuki Mochida
  • Toshiaki Ebina
  • Tsukasa Kobayashi
  • Kohei Matsushita
  • Katsumi Matsumoto
  • Noriko Kawasaki
  • Mie Shimura
  • Yasuo Ohkusu
  • Shinichi Sumita
  • Kazuo Kimura
  • Tomio Inoue
  • Satoshi Umemura
چکیده

OBJECTIVES This study sought to evaluate an imaging approach using gated 99mTc-MIBI (MIBI) SPECT and gated 18F-FDG (FDG) PET for assessment of myocardial viability and cardiac function. METHODS Forty-eight patients (38 men, mean age 68.1 +/- 9.6 years) underwent ECG-gated FDG PET and MIBI SPECT within a week. The baseline diagnoses were coronary artery disease (31), mitral regurgitation (1), paroxysmal arrhythmia (10), and dilated cardiomyopathy (6). The gated FDG PET data were analyzed using pFAST software, and the gated MIBI SPECT data were analyzed using QGS software. Fifteen patients were diagnosed with myocardial infarction, and follow-up study was performed to assess the functional outcome four months later. An improvement in LVEF of >5% was defined as significant. The LV myocardium was divided into 17 segments, and regional defect scores were visually assessed using a 4-point scale for each segment (0 = normal, 1 = mildly reduced, 2 = moderately reduced, 3 = absent). A segment with a greater defect score on MIBI SPECT than on FDG PET was defined as a mismatch. The patients were divided into two groups: those with at least two mismatched segments (MM-group), and those with none or one (M-group). RESULTS LVEF, EDV and ESV measured by gated FDG PET were highly correlated with those obtained by gated MIBI SPECT (r = 0.848, 0.855 and 0.911, p < 0.0001, respectively). The mean values of LVEF did not differ significantly, but EDV and ESV obtained by gated FDG PET were significantly grater than those obtained by gated MIBI SPECT (p < 0.0001). In 15 patients diagnosed with myocardial infarction, a significant association (p < 0.05) was found between the relative uptake of FDG PET and MIBI SPECT and the functional outcome 4 months later. Global LV function improved in 6 of the 8 patients showing mismatch but in only 1 of the 7 patients with matched defects, resulting in a sensitivity of 86% and specificity of 75%. The overall accuracy to predict global functional outcome was high (80%). CONCLUSION This imaging approach allows accurate evaluation of myocardial viability. Furthermore, the high correlations of gated FDG PET and gated MIBI SPECT measurements hold promise for the assessment of left ventricular function using gated FDG PET.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the myocardial perfusion and wall motion results by ECG-Gated 99mTc-MIBI SPECT, before and after CABG for evaluation of myocardial viability [Persian]

It is of value to determine the amount of viable myocardial tissue in patients suffering from chronic coronary artery disease and ventricular dysfunction. Having the capability of evaluating both myocardial perfusion and function, simultaneously, myocardial scanning by ECG-Gated is an appropriate method for this purpose. The aim of this study was to compare the results of myocardial perfu...

متن کامل

The value of the Gated 99mTc-MIBI SPECT in differentiation of fixed myocardial lesions [Persian]

Fixed myocardial defects in both stress and rest images, could be artifactual as a result of soft tissue attenuation. To increase specificity and identify the false positive results, we used gated technique to evaluate the wall motion and wall thickening as an index to differentiate real ischemic lesions from artifactual defects. 93 patients were studied. In 46 patients (48.8%) fixed perf...

متن کامل

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

متن کامل

Gated 99mTc-MIBI myocardial perfusion SPECT in patients with right bundle branch block but without evidence of coronary artery disease

Introduction: We aimed to investigate the effect of right bundle branch block (RBBB) on perfusion and functional parameters in dipyridamole stress/rest Tc99m-MIBI gated myocardial perfusion SPECT (GSPECT) which may be helpful in interpretation of myocardial perfusion imaging. Methods: We studied 73 patients with low pre-test likelihood of coronary artery disease in two groups:  38 patients wit...

متن کامل

Assessment of the integrated role of myocardium perfusion gated SPECT study in patient with parathyroid adenoma by 99mTc-sestamibi

Introduction: The purpose of this study is to assess the integrated role of scintigraphy by Tc99m MIBI in diagnosis of parathyroid adenoma and its impacts on the myocardium, and to evaluate whether myocardium perfusion gated SPECT study could be a complementary routine workup for patient with positive parathyroid adenoma on Tc99m MIBI parathyroid scan. Methods: Rest myocardium perfusion gated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 18 5  شماره 

صفحات  -

تاریخ انتشار 2004