Scatterer Size Estimation Using a Generalized Ultrasound Attenuation-compensation Function to Correct for Focusing
نویسنده
چکیده
The frequency statistics of the backscattered waveform observed between tissue boundaries can be matched to a model to estimate the characteristic size of the scatterer in the tissue region of interest. In the past, the models have all assumed plane wave propagation requiring the use of unfocused or weakly focused sources in the experiment. In our work, we challenged this assumption by re-deriving the scattering equations assuming that the focused field can be accurately modeled as a 3D Gaussian distribution in addition to the traditional assumptions that the scatterers are a sufficient distance from the source and that the field is approximately constant across the scatterer. We showed that correcting for focusing when estimating the scatterer size only requires a generalized attenuation-compensation function that includes the impact of focusing along the beam axis. We then generated computer simulations to aid in the understanding of the impact of diffraction along the beam axis and compared the performance of our attenuation-compensation function to the performance of previously proposed attenuationcompensation functions for various levels of focusing (f/1, f/2, f/4), attenuation (0.05 to 1 dB/cm/MHz), and rectangular window length used to gate the time domain signal (1 to 13 mm). The generalized attenuation-compensation function yielded results accurate between 2% and 7.2% while the traditional attenuation-compensation functions that neglected focusing had errors greater than 50% for moderate attenuation and window lengths.
منابع مشابه
Scatterer size estimation in pulse-echo ultrasound using focused sources: theoretical approximations and simulation analysis.
The speckle in ultrasound images has long been thought to contain information related to the tissue microstructure. Many different investigators have analyzed the frequency characteristics of the backscattered signals to estimate the scatterer acoustic concentration and size. Previous work has been mostly restricted to unfocused or weakly focused ultrasound sources, thus limiting its implementa...
متن کاملScatterer size estimation in pulse-echo ultrasound using focused sources: calibration measurements and phantom experiments.
In a companion paper [T. A. Bigelow and W. D. O'Brien Jr., J. Acoust. Soc. Am. 116, 578 (2004)], theory, supported by simulations, showed that accurate scatterer size estimates could be obtained using highly focused sources provided that the derived generalized attenuation-compensation function was used and the velocity potential field near the focus could be approximated as a three-dimensional...
متن کاملSignal processing strategies that improve performance and understanding of the quantitative ultrasound SPECTRAL FIT algorithm.
Quantifying the size of the tissue microstructure using the backscattered power spectrum has had limited success due to frequency-dependent attenuation along the propagation path, thus masking the frequency dependence of the scatterer size. Previously, the SPECTRAL FIT algorithm was developed to solve for total attenuation and scatterer size simultaneously [Bigelow et al., J. Acoust. Soc. Am. 1...
متن کاملEstimation of total attenuation and scatterer size from backscattered ultrasound waveforms.
Quantitative ultrasound techniques using backscattered echoes have had limited success in vivo due to the frequency-dependent attenuation along the entire propagation path masking the frequency dependence of the backscatter. Herein, total attenuation and scatterer size are estimated simultaneously by an analysis of the in vivo backscattered power spectrum using two approaches. The simulations u...
متن کاملImpact of local attenuation approximations when estimating correlation length from backscattered ultrasound echoes.
Estimating the characteristic correlation length of tissue microstructure from the backscattered power spectrum could improve the diagnostic capability of medical ultrasound. Previously, size estimates were obtained after compensating for source focusing, the frequency-dependent attenuation along the propagation path (total attenuation), and the frequency-dependent attenuation in the scattering...
متن کامل