Optimum Method to Determine Gamma Activity in 200 Liter Drums – In-toto Measurement or Extracting a Sample
نویسنده
چکیده
In the process of decommissioning contaminated facilities, and in the conduct of normal operations involving radioactive material, it is frequently required to measure radioactivity in large containers such as 200 liter drums. For solid material, it is quite unusual for the radioactivity to be homogeneously distributed throughout the container. One way to derive the concentration of radioactivity within the container is to extract a sample for subsequent measurement in the laboratory. Another way is to use gamma spectroscopy and assay the entire container, or in-toto measurement. This paper examines the process of determining the best way to estimate the activity within the container, and gives quantitative estimates of measurement uncertainty for various conditions of radioactivity contained within 200 liter drums. When the contents of the container are not homogeneous, the sampling uncertainty is likely to be larger than the in-toto measurement uncertainty.
منابع مشابه
Optimal Conditions for Extraction and Purification of Penicillinase Enzyme
Background and Objective: The present study aimed to evaluate the optimum conditions for extracting and purifying penicillinase enzyme. The enzyme source was Bacillus licheniformis 6346 obtained from the Iranian Research Organization for Science and Technology. Materials and Methods: B. licheniformis was cultured in a medium containing mineral salts, nitrogen compounds, and cultured carbon sou...
متن کاملMeasurement of PDP Drums Evaluate Program Isotopic
Measurement of nonhomogeneous special nuclear material using passive gamma techniques is difficult because it is not practical to develop standards with the characteristics of the samples. Each sample is different. And the samples must be measured nondestructively. Modeling methods must be used. The modeling methods assume homogenous distribution of radioactive and matrix material within the co...
متن کاملOptimization of measurement counting time in Gamma-ray spectrometry of soil samples
The method of optimal measurement counting time in Gamma spectrometry for soil samples was studied. Gamma spectrometry was done based on minimum detectable activity using the HPGe- p type with efficiency of 30% and FWHM 1.7keV (for 1.33 MeV 60Co). The samples were IAEA-RG Th-1, IAEA-RGU-1 and IAEA-RGK-1 prepared in bottles. The measurements were done for 12 different counting times from 5 min t...
متن کاملDetermination of Optimum Planar Imaging Parameters for Small Structures with Diameters Less Than the Resolution of the Gamma Camera
Introduction: The limited spatial resolution of the gamma camera hinders the absolute quantification of planar images of small structures. The imaged structures are affected by partial volume effects (PVEs), which can spread activity and lead to underestimation of the regional distribution. The use of optimum planar parameters reduces the impact of the limited spatial resolution of the gamma c...
متن کاملThe Effect of Echinops Lasiolepis Extracts, Native Plant of Yazd Province, on Peripheral Blood Mononuclear Cell Proliferation and IFN-γ Secretion
Background and Aims: The present study was performed to investigate the effect of Echinops lasiolepis extract on peripheral blood mononuclear cells (PBMCs) proliferation and interferon (IFN)-&gamma secretion. Materials and Methods: PBMCs were obtained from three healthy volunteers and cultured in presence of Echinops lasiolepis methanol extract in different concentrations of 0.1, 1, 10, 100 ...