Semi-automated closed-circuit bladder wash-out pump.

نویسندگان

  • J A Bushman
  • S Askill
  • D Wallace
چکیده

write: A pump has been constructed as a possible solution to a problem posed by one of us (D.W.)-namely, to produce a device which would wash out the bladder after prostatectomy vwithout breaking the closed drainage system (which could result ia an infection) and which could be used by relatively unskilled staff. The pump with its associated valves is composed of only two parts-a piston and a cylinder (figs. 1 and 2). The piston has two functions, which are divided between its upper and lower halves. The lower half of the piston is grooved and the relation between this groove and the ports in the cylinder wall determines the source and destination of fluids entering and leaving the cylinder. A peg in the cylinder wall engages in another set of grooves cut in the upper half of the piston. This engagement allows only certain movements of the piston relative to the cylinder , so that the order of pumping movements and direction of fluid movement in and out of the cylinder are predetermined. The top of the piston is in the form of a combined handle and pointer to indicate the function of the pump in that particular position. 0 W FIG. 2-Right: Groove in piston is shown opposite two ports in cylinder. Left: Diagram of "gate" cut in upper half of piston which is engaged by peg in wail of cylinder, thus limiting its movement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Closed circuit rebreathing to achieve inert gas wash-in for multiple breath wash-out

Multiple breath wash-out (MBW) testing requires prior wash-in of inert tracer gas. Wash-in efficiency can be enhanced by a rebreathing tracer in a closed circuit. Previous attempts to deploy this did not account for the impact of CO2 accumulation on patients and were unsuccessful. We hypothesised that an effective rebreathe wash-in could be delivered and it would not alter wash-out parameters. ...

متن کامل

Desflurane consumption during automated closed-circuit delivery is higher than when a conventional anesthesia machine is used with a simple vaporizer-O2-N2O fresh gas flow sequence

BACKGROUND The Zeus® (Dräger, Lübeck, Germany), an automated closed-circuit anesthesia machine, uses high fresh gas flows (FGF) to wash-in the circuit and the lungs, and intermittently flushes the system to remove unwanted N₂. We hypothesized this could increase desflurane consumption to such an extent that agent consumption might become higher than with a conventional anesthesia machine (Anest...

متن کامل

Synthetic Biology Based on Genetic Logic Circuit, Using the Expression of Drug Resistance, BCRP Pump in MCF-7 Cancer Cell Line

Biological circuits are developed as biological parts within a cell to carry out logical functions resembling those studied in electronics circuits. These circuits can be performed as a method to vary cellular functions, to develop cellular responses to environmental conditions, or to regulate cellular developments. This research explored the possibility of synthetic biology based on the geneti...

متن کامل

Synthetic Biology Based on Genetic Logic Circuit, Using the Expression of Drug Resistance, BCRP Pump in MCF-7 Cancer Cell Line

Biological circuits are developed as biological parts within a cell to carry out logical functions resembling those studied in electronics circuits. These circuits can be performed as a method to vary cellular functions, to develop cellular responses to environmental conditions, or to regulate cellular developments. This research explored the possibility of synthetic biology based on the geneti...

متن کامل

Study on regurgitation of a bearing-less mini axial aortic valvo-pump with closed impeller

The back-flow of an aortic valvo-pump will reduce the pumping flow rate but can wash out the gap between the rotor and the stator, and thus can improve the antithrombogenicity of the device. To investigate the regurgitation of a 23mm OD aortic valvo-pump, its closed impeller was replaced by a cylinder and hereby the valvopump had lost its pumping function. The pressure head crossing the aortic ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British medical journal

دوره 4 5891  شماره 

صفحات  -

تاریخ انتشار 1973