Numerical study of a macroscopic finite pulse model of the diffusion MRI signal.

نویسندگان

  • Jing-Rebecca Li
  • Hang Tuan Nguyen
  • Dang Van Nguyen
  • Houssem Haddar
  • Julien Coatléven
  • Denis Le Bihan
چکیده

Diffusion magnetic resonance imaging (dMRI) is an imaging modality that probes the diffusion characteristics of a sample via the application of magnetic field gradient pulses. The dMRI signal from a heterogeneous sample includes the contribution of the water proton magnetization from all spatial positions in a voxel. If the voxel can be spatially divided into different Gaussian diffusion compartments with inter-compartment exchange governed by linear kinetics, then the dMRI signal can be approximated using the macroscopic Karger model, which is a system of coupled ordinary differential equations (ODEs), under the assumption that the duration of the diffusion-encoding gradient pulses is short compared to the diffusion time (the narrow pulse assumption). Recently, a new macroscopic model of the dMRI signal, without the narrow pulse restriction, was derived from the Bloch-Torrey partial differential equation (PDE) using periodic homogenization techniques. When restricted to narrow pulses, this new homogenized model has the same form as the Karger model. We conduct a numerical study of the new homogenized model for voxels that are made up of periodic copies of a representative volume that contains spherical and cylindrical cells of various sizes and orientations and show that the signal predicted by the new model approaches the reference signal obtained by solving the full Bloch-Torrey PDE in O(ε(2)), where ε is the ratio between the size of the representative volume and a measure of the diffusion length. When the narrow gradient pulse assumption is not satisfied, the new homogenized model offers a much better approximation of the full PDE signal than the Karger model. Finally, preliminary results of applying the new model to a voxel that is not made up of periodic copies of a representative volume are shown and discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parameter estimation using macroscopic diffusion MRI signal models.

Macroscopic models of the diffusion MRI (dMRI) signal can be helpful to understanding the relationship between the tissue microstructure and the dMRI signal. We study the least squares problem associated with estimating tissue parameters such as the cellular volume fraction, the residence times and the effective diffusion coefficients using a recently developed macroscopic model of the dMRI sig...

متن کامل

Understanding the concept of diffusion time for finite pulse sequences in diffusion MRI: case of the Karger model

Diffusion magnetic resonance imaging (dMRI) is an imaging modality that probes the diffusion characteristics of a sample via the application of magnetic field gradient pulses. When the duration of the diffusion-encoding gradient pulses is small compared to the delay between the pulses (the narrow pulse assumption), the concept of the probed diffusion time is easy to define. However, when the na...

متن کامل

A numerical treatment of a reaction-diffusion model of spatial pattern in the embryo

In this work the mathematical model of a spatial pattern in chemical and biological systems is investigated numerically. The proposed model considered as a nonlinear reaction-diffusion equation. A computational approach based on finite difference and RBF-collocation methods is conducted to solve the equation with respect to the appropriate initial and boundary conditions. The ability and robust...

متن کامل

Prediction of Service Life in Concrete Structures based on Diffusion Model in a Marine Environment using Mesh Free, FEM and FDM Approaches

Chloride-induced corrosion is a key factor in the premature corrosion of concrete structures exposed to a marine environment. Fick's second law of diffusion is the dominant equation to model diffusion of chloride ions. This equation is traditionally solved by Finite Element Method (FEM) and Finite Difference Method (FDM). Although these methods are robust and efficient, they may face some numer...

متن کامل

A Macroscopic Model Including Membrane Exchange for Diffusion MRI

Diffusion Magnetic Resonance Imaging is a promising tool to obtain useful information on the microscopic structure and has been extensively applied to biological tissues. We establish a new macroscopic model from homogenization theory for the complex transverse water proton magnetization in a voxel due to diffusion-encoding magnetic field gradient pulses in the case of intermediate water exchan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 248  شماره 

صفحات  -

تاریخ انتشار 2014