چکیده
Laser ignition experiments have been performed using the Ml98 towed howitzer as the test bed. The first component was to evaluate the performance of two modified M3 Al bag charges, each of which had the standard igniter pad replaced with a propellant-filled tube designed to pressurize rapidly and generate sufficient gas and pressure for prompt ignition. These experiments were successful but not remarkable, with ignition times faster than the average for clean-burning igniter (CBI) pad ignition. Along with these rounds, standard rounds were fired to gain more experience with laser ignition of the Ml 98 in preparation for interfacing a digital fire control computer with the laser ignition system. All these experiments were done with a pulsed neo-dymium: ytterbium aluminum garnet (Nd: YAG) laser similar to the one developed for the XM297 cannon. In the third part of the program, a continuous semiconductor diode laser was used to ignite five Zone 3 modular artillery cannon system (MACS) charges. Delay times from 355 to 733 ms were recorded. No degradation of the laser was noted from shock/vibration effects.
منابع مشابه
معرفی و فاکتورهای موثر بر روشهای آغازش لیزری مواد پرانرژی
Military equipments containing energetic materials are conventionally ignited by heat and through an explosive train. Heat is often created by a flame or electricity from a resistive wire. Energetic materials used in these systems due to electrical inseparation from the surrounded medium are exposed to different electromagnetic radiations and so unexpected ignitions of them are probable. In thi...
متن کاملTNT particle size distributions from detonated 155-mm howitzer rounds.
To achieve sustainable range management and avoid or minimize environmental contamination, the Army needs to know the amount of explosives deposited on ranges from different munitions and how these are degraded and transported under different geological and climatic conditions. The physical form of the deposited explosives has a bearing on this problem, yet the shapes and size distributions of ...
متن کاملSafe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review
Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...
متن کاملVelocity Uniformity Obtained with 13 Gr Modified M 22 Primers in the 75 Mm Gun
Twenty rounds vere fired with the 15 gr. Modified M22 primers. A mean deviation of 2 f/s or an estimated probable error in velocity of 1.5 f/s was obtained. An explanation of this low dispersion in velocity is tentatively offered. Authority was ohtnin^d to fire a 20 round uniformity series in a 75 mm Gun Mod. 1G97 using charges of S.P. FNH, powder lot 5530, ignited with a 15 gr. Modified M22 pr...
متن کاملA portable shield for a neutron howitzer used for instructional and research purposes.
Neutron howitzers are routinely used in universities to activate samples for instructional laboratory experiments on radioactivity. They are also a convenient source of neutrons and gammas for research purposes, but they must be used with caution. This paper describes the modeling, design, construction, and testing of a portable, economical shield for a 1.0 Curie neutron howitzer. The Monte Car...
متن کامل