Comparison of protected isolation techniques between the laminar airflow room and the life island unit.

نویسندگان

  • T Nagao
  • M Komatsuda
  • K Yamauchi
  • H Nozaki
  • S Arimori
  • S Sawamura
  • A Ozawa
  • A Shotsu
  • S Sasaki
چکیده

The use of laminar airflow rooms and a life island unit for comprised patients was evaluated. Six patients spent a total of 170 days in the laminar airflow rooms and 112 days in the life island unit, and none acquired any exogenous infection. Patients were febrile for 7 out of 170 days (4.1%) in the laminar airflow rooms and 4 out of 112 days (3.6%) in the life island unit. No significant difference in the rate of deposition of organisms on settling plates and surface samples was found between the laminar airflow rooms and the life island unit. The advantages of the laminar airflow rooms are freedom of movement for patients and hospital personnel and patient comfort, while those of the life island unit are much lower purchasing and operating costs and portability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison between Temperature-Controlled Laminar Airflow Device and a Room Air-Cleaner in Reducing Exposure to Particles While Asleep

People spend approximately one third of their life sleeping. Exposure to pollutants in the sleep environment often leads to a variety of adverse health effects, such as development and exacerbation of asthma. Avoiding exposure to these pollutants by providing a sufficient air quality in the sleep environment might be a feasible method to alleviate these health symptoms. We performed full-scale ...

متن کامل

Comparison of three distinct clean air suits to decrease the bacterial load in the operating room: an observational study

BACKGROUND Lowering air-borne bacteria counts in the operating room is essential in prevention of surgical site infections in orthopaedic joint replacement surgery. This is mainly achieved by decreasing bacteria counts through dilution, with appropriate ventilation and by limiting the bacteria carrying skin particles, predominantly shed by the personnel. The aim of this study was to investigate...

متن کامل

Steady Flow Through Modeled Glottal Constriction

The airflow in the modeled glottal constriction was simulated by the solutions of the Navier-Stokes equations for laminar flow, and the corresponding Reynolds equations for turbulent flow in generalized, nonorthogonal coordinates using a numerical method. A two-dimensional model of laryngeal flow is considered and aerodynamic properties are calculated for both laminar and turbulent steady flows...

متن کامل

The effect of laminar air flow and door openings on operating room contamination.

We evaluate the association of laminar airflow (LAF) and OR traffic with intraoperative contamination rates. Two sterile basins were placed in each room during 81 cases, one inside and one outside the LAF. One Replicate Organism Detection and Counting (RODAC) plate from each basin was sent for culture at successive 30-minute intervals from incision time until wound closure. At successive 30-min...

متن کامل

Isolation and characterization of bacteria and fungi in ambient air of Qeshm Island

Introduction: Many studies have shown an association between respiratory distress, allergic reactions and the presence of bacteria and fungi in air. We aimed to compare the air micro flora of Qeshm Island with those of other provinces. Methods: This experimental study was consisted of grown colonies on PDA, SC media for fungi and BHI, TSA media for bacteria. Samples were taken by Air Trapping...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Tokai journal of experimental and clinical medicine

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 1981