Software Based Matching of X-ray Images and 3D Models of Knee Prostheses

نویسندگان

  • Jan Bredow
  • Pauline Dorda
  • Ralf Westphal
  • K. Sircar
  • Klaus Schlüter-Brust
  • Peer Eysel
  • Friedrich M. Wahl
چکیده

BACKGROUND Revision joint replacements are challenging surgical tasks. Knowing the exact type of primary prosthesis is essential to avoid long preoperative organisation, long operation times, and especially loss of bone and soft-tissue during operation. In daily routine there is often no information about the primary prosthesis. OBJECTIVE We are developing methods for identifying implanted prostheses from x-ray images by means of matching template images generated from prosthesis CAD data. METHODS The application is separated into three major components: The "Template Image Generation" adds 3d models of endoprostheses to a database. The "X-ray Image Segmentation" extracts endoprostheses from provided sets of x-ray images. The "Template Matching" finds the best matching prosthesis types in the data base. At the current stage, one prosthesis model (Corin, Knee ProthesisUniglide) was used for evaluating these algorithms. RESULTS Very accurate identifications with accuracies of about 90% for lateral and over 70% for frontal images could be achieved. CONCLUSIONS The current results of this feasibility study are very promising. A reliable and fast prosthesis identification process seems realistic to support the surgeon when planning and performing revision arthroplasty. Further improvements of segmentation accuracies and extending the prosthesis data base are intended next steps towards this goal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Segmentation on 3D-to-2D Registration of Implant Models in X-ray Images

In many biomedical applications, it is desirable to estimate the three dimensional (3D) position and orientation (pose) of a metallic rigid object (such as a knee or hip implant) from its projection in a two dimensional (2D) X-ray image. If the geometry of the object is known, as well as the details of the image formation process, then the pose of the object with respect to the sensor can be de...

متن کامل

Medical Imaging Teacher: A Program to Simulate X-Ray Images of the Body by Considering kVp, mAs, and FFD Values

Introduction: Teaching styles and methods have been constantly changing in the recent years. In the 1980s and 90s, the world was introduced to various developed devices, such as smart boards and early generation smart phones that had an immediate innovative effect on education. These advancements has resulted in a considerable improvement in the current educational techniques. The innovations i...

متن کامل

Comparison of Diagnostic Value of Cast Analyzer X Iranian Software versus Curve Expert Software for Arch Form Construction based on Mathematical Models

  Objective: For the assessment of primary arch form, different methods have been used including qualitative classifications, inter-canine and inter-molar widths and quantitative and numerical methods using mathematical models. The purpose of this study was to compare the validity and reliability of Cast Analyzer X Iranian software with those of Curve Expert Professional version 1.1 for arch fo...

متن کامل

Can magnetic resonance imaging-derived bone models be used for accurate motion measurement with single-plane three-dimensional shape registration?

The purpose of this study was to compare three-dimensional (3D) kinematic measurements from single-plane radiographic projections using bone models created from magnetic resonance imaging (MRI) and computed tomography (CT). MRI is attractive because there is no ionizing radiation, but geometric field distortion and poor bone contrast degrade model fidelity compared to CT. We created knee bone m...

متن کامل

Impact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography

Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Technology and health care : official journal of the European Society for Engineering and Medicine

دوره 22 6  شماره 

صفحات  -

تاریخ انتشار 2012