Prosthesis sizing for transcatheter aortic valve implantation--comparison of three dimensional transesophageal echocardiography with multislice computed tomography.

نویسندگان

  • Oliver Husser
  • Andreas Holzamer
  • Markus Resch
  • Dierk H Endemann
  • Julio Nunez
  • Vicente Bodi
  • Christof Schmid
  • Günter A J Riegger
  • Holger Gössmann
  • Okka Hamer
  • Christian Stroszczynski
  • Andreas Luchner
  • Michael Hilker
  • Christian Hengstenberg
چکیده

BACKGROUND The complex anatomy of the aortic annulus warrants the use of three dimensional (3D) modalities for prosthesis sizing in transcatheter aortic valve implantation (TAVI). Multislice computed tomography (MSCT) has been used for this purpose, but its use may be restricted because of contrast administration. 3D transesophageal echocardiography (3D-TEE) lacks this limitation and data on comparison with MSCT is scarce. We compared 3D-TEE with MSCT for prosthesis sizing in TAVI. METHODS Aortic annulus diameters in the sagittal and coronal plane and annulus areas in 3D-TEE and MSCT were compared in 57 patients undergoing TAVI. Final prosthesis size was left at the operator's discretion and the agreement with 3D-TEE and MSCT was calculated. RESULTS Sagittal diameters on 3D-TEE and MSCT correlated well (r=.754, p<.0001) and means were comparable (22.3±2.1 vs. 22.5±2.3 mm; p=0.2; mean difference: -0.3 mm [-3.3-2.8]). On 3D-TEE, coronal diameter and annulus area were significantly smaller (p<.0001 for both) with moderate correlation (r=0.454 and r=0.592). Interobserver variability was comparable for both modalities. TAVI was successful in all patients with no severe post-procedural insufficiency. Final prosthesis size was best predicted by sagittal annulus diameters in 84% and 79% by 3D-TEE and MSCT, respectively. Agreement between both modalities was 77%. CONCLUSIONS Annulus diameters and areas for pre-procedural TAVI assessment by 3D-TEE are significantly smaller than MSCT with exception of sagittal diameters. Using sagittal diameters, both modalities predicted well final prosthesis size and excellent procedural results were obtained. 3D-TEE can thus be a useful alternative in patients with contraindications to MSCT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

FDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device.

can Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. J Am Soc Echocardiogr 1999;12: 884–900. 21. Wong DT, Bertaso AG, Liew GY, Thomson VS, Cunnington MS, Richardson JD et al. Relationship of aortic annular eccentricity and paravalvular regurg...

متن کامل

Preparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for improved valve sizing.

OBJECTIVES This study sought to evaluate whether supra-aortic angiography during preparatory balloon aortic valvuloplasty (BAV) improves valve sizing. BACKGROUND Current recommendations for valve size selection are based on annular measurements by transesophageal echocardiography and computed tomography, but paravalvular aortic regurgitation (PAR) is a frequent problem. METHODS Data of 270 ...

متن کامل

Transfemoral aortic valve implantation in severe aortic stenosis patients with prior mitral valve prosthesis

INTRODUCTION Transcatheter aortic valve implantation for severe symptomatic aortic stenosis in patients with a previous mitral valve prosthesis is technically challenging, and pre-procedural comprehensive assessment of these patients before transcatheter aortic valve implantation is vital for an uncomplicated and successful procedure. AIM We want to share our experience with transcatheter aor...

متن کامل

Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation.

BACKGROUND Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus. METHODS We evaluated the theoretical impact of the measurement of the annulus diamete...

متن کامل

Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation.

OBJECTIVES To compare aortic annulus diameters obtained by 3D transesophageal echocardiography (TEE) with 2D-TEE and the impact on prosthesis size selection in transcatheter aortic valve implantation (TAVI). BACKGROUND In TAVI the aortic annulus diameter determines prosthesis size. The ideal modality for annulus assessment has not been defined yet. METHODS Annulus diameters in 2D-TEE (long-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of cardiology

دوره 168 4  شماره 

صفحات  -

تاریخ انتشار 2013