Early results of posterior-stabilised NexGen Legacy total knee arthroplasty.

نویسندگان

  • D Ip
  • W C Wu
  • W L Tsang
چکیده

OBJECTIVE To retrospectively assess the early results of the NexGen Legacy posterior-stabilised total knee prosthesis, which is a newer version of the Insall-Burstein II posterior-stabilised implant. METHODS 48 consecutive elderly patients had 60 NexGen Legacy posterior-stabilised total knees. The mean follow-up duration was 21 months. Clinical evaluation was performed according to the Knee Society scores and a scoring system for patellofemoral articulation; radiographic assessment followed the guidelines of the Knee Society. Special emphasis was given to any patellofemoral complications, such as patellar clunk syndrome, patellar maltracking, and other disorders of the extensor mechanism. RESULTS Only one patient had mild patellofemoral anterior knee pain at the latest follow-up; 2 patients had patellofemoral crepitus but no pain. No patellar clunk or any other complication of the patellofemoral articulation, such as patellar fracture or subluxation was found. The mean preoperative and postoperative Knee Society scores were 60 and 85 respectively. The mean postoperative knee flexion was 115 degrees. CONCLUSION The overall early results from using the new implant were good, probably because of changes in design of the intercondylar box and its associated cam-and-post mechanism, and a more anatomic trochlea surface, so that the trochlea accommodates the natural patella.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty.

We measured the contact areas and contact stresses at the post-cam mechanism of a posterior-stabilised total knee arthroplasty when a posterior force of 500 N was applied to the Kirschner Performance, Scorpio Superflex, NexGen LPS Flex Fixed, and NexGen LPS Flex Mobile knee systems. Measurements were made at 90 degrees, 120 degrees, and 150 degrees of flexion both in neutral rotation and 10 deg...

متن کامل

The NexGen LPS-flex to the knee prosthesis at a minimum of three years.

We carried out a prospective study to assess the clinical outcome, complications and survival of the NexGen Legacy posterior-stabilised-Flex total knee replacement (TKR) in a consecutive series of 278 knees between May 2003 and February 2005. Mean follow-up for 259 TKRs (98.2%) was 3.8 years (3.0 to 4.8). Annual follow-up showed improvement in the Knee Society scores (paired t-test, p < 0.05). ...

متن کامل

Gender-specific high-flexion knee prosthesis in Indian women: a prospective randomised study.

PURPOSE To compare outcomes in Indian women who underwent total knee arthroplasty (TKA) using the standard Legacy Posterior Stabilised (LPS) versus the gender-specific LPS high-flexion knee prosthesis. METHODS 100 women (200 knees) aged 60 to 80 years with an arc of flexion of ≥90º underwent simultaneous sequential TKA for primary osteoarthritis of both knees. They were randomised to receive ...

متن کامل

A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components.

Modifications in the design of knee replacements have been proposed in order to maximise flexion. We performed a prospective double-blind randomised controlled trial to compare the functional outcome, including maximum knee flexion, in patients receiving either a standard or a high flexion version of the NexGen legacy posterior stabilised total knee replacement. A total of 56 patients, half of ...

متن کامل

High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement.

We have examined the results obtained with 72 NexGen legacy posterior stabilised-flex fixed total knee replacements in 47 patients implanted by a single surgeon between March 2003 and September 2004. Aseptic loosening of the femoral component was found in 27 (38%) of the replacements at a mean follow-up of 32 months (30 to 48) and 15 knees (21%) required revision at a mean of 23 months (11 to 4...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 11 1  شماره 

صفحات  -

تاریخ انتشار 2003