Investigation of a clinical PET detector module design that employs large-area avalanche photodetectors.

نویسندگان

  • Hao Peng
  • Peter D Olcott
  • Virginia Spanoudaki
  • Craig S Levin
چکیده

We investigated the feasibility of designing an Anger-logic PET detector module using large-area high-gain avalanche photodiodes (APDs) for a brain-dedicated PET/MRI system. Using Monte Carlo simulations, we systematically optimized the detector design with regard to the scintillation crystal, optical diffuser, surface treatment, layout of large-area APDs, and signal-to-noise ratio (SNR, defined as the 511 keV photopeak position divided by the standard deviation of noise floor in an energy spectrum) of the APD devices. A detector prototype was built comprising an 8 × 8 array of 2.75 × 3.00 × 20.0 mm3 LYSO (lutetium-yttrium-oxyorthosilicate) crystals and a 22.0 × 24.0 × 9.0 mm3 optical diffuser. From the four designs of the optical diffuser tested, two designs employing a slotted diffuser are able to resolve all 64 crystals within the block with good uniformity and peak-to-valley ratio. Good agreement was found between the simulation and experimental results. For the detector employing a slotted optical diffuser, the energy resolution of the global energy spectrum after normalization is 13.4 ± 0.4%. The energy resolution of individual crystals varies between 11.3 ± 0.3% and 17.3 ± 0.4%. The time resolution varies between 4.85 ± 0.04 (center crystal), 5.17 ± 0.06 (edge crystal), and 5.18 ± 0.07 ns (corner crystal). The generalized framework proposed in this work helps to guide the design of detector modules for selected PET system configurations, including scaling the design down to a preclinical PET system, scaling up to a whole-body clinical scanner, as well as replacing APDs with other novel photodetectors that have higher gain or SNR such as silicon photomultipliers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A dual-ended readout PET detector module based on GAPDs with large-area microcells

The use of a dual-ended readout PET detector module based on Geiger-mode avalanche photodiodes (GAPDs) with large-area microcells was proposed to obtain high photon detection efficiency (PDE) and overcome energy non-linearity problems. A simulation study was performed and experimental measurement were taken for the singleand dual-ended PET detector modules consisting of the two types of GAPDs w...

متن کامل

Performance measurements of a depth-encoding PET detector module based on position-sensitive avalanche photodiode read-out.

We are developing a high-resolution, high-efficiency positron emission tomography (PET) detector module with depth of interaction (DOI) capability based on a lutetium oxyorthosilicate (LSO) scintillator array coupled at both ends to position-sensitive avalanche photodiodes (PSAPDs). In this paper we present the DOI resolution, energy resolution and timing resolution results for complete detecto...

متن کامل

Influence of temperature and bias voltage on the performance of a high resolution PET detector built with position sensitive avalanche photodiodes

We evaluate the performance of an 8 × 8 array of 0.9 × 0.9 × 1 mm 3 cerium doped lutetium oxyothosilicate (LSO) crystals coupled to a position sensitive avalanche photodiode (PS-APD) as a function of bias voltage and temperature. We use this detector to develop a general methodology to optimize bias voltage, temperature, and gain for PET detectors using semiconductor photodetectors. This detect...

متن کامل

Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

UNLABELLED PET and MRI are powerful imaging techniques that are largely complementary in the information they provide. We have designed and built a MR-compatible PET scanner based on avalanche photodiode technology that allows simultaneous acquisition of PET and MR images in small animals. METHODS The PET scanner insert uses magnetic field-insensitive, position-sensitive avalanche photodiode ...

متن کامل

Development of a position decoder circuit for PET consisting of GAPD arrays

Use of channel reduction techniques that reduce the number of signals transmitted to a data acquisition (DAQ) module can lead to more efficient use of the DAQ module for PET with numerous readout channels. The purpose of this study was to develop a position decoder circuit (PDC) with a capacity to output the digital address and analog pulse of one interacted channel from numerous PET outputs. A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 56 12  شماره 

صفحات  -

تاریخ انتشار 2011