Human gravity-gradient noise in interferometric gravitational-wave detectors

نویسندگان

  • Kip S. Thorne
  • Carolee J. Winstein
چکیده

Among all forms of routine human activity, the one which produces the strongest gravity-gradient noise in interferometric gravitational-wave detectors ~e.g. LIGO! is the beginning and end of weight transfer from one foot to the other during walking. The beginning and end of weight transfer entail sharp changes ~time scale t;20 msec! in the horizontal jerk ~first time derivative of acceleration! of a person’s center of mass. These jerk pairs, occurring about twice per second, will produce gravity-gradient noise in LIGO in the frequency band 2.5 Hz& f &1/(2t).25 Hz with the form ASh( f );0.6310 Hz( f /10 Hz)@( i(ri/10 m)]. Here the sum is over all the walking people, ri is the distance of the i’th person from the nearest interferometer test mass, and we estimate this formula to be accurate to within a factor 3. To ensure that this noise is negligible in advanced LIGO interferometers, people should be prevented from coming nearer to the test masses than r.10 m. A r.10 m exclusion zone will also reduce to an acceptable level gravity gradient noise from the slamming of a door and the striking of a fist against a wall. The dominant gravity-gradient noise from automobiles and other vehicles is probably that from decelerating to rest. To keep this below the sensitivity of advanced LIGO interferometers will require keeping vehicles at least 30 m from all test masses. @S0556-2821~99!03418-9#

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Benefits of Artificially Generated Gravity Gradients for Interferometric Gravitational-Wave Detectors

We present an approach to experimentally evaluate gravity gradient noise, a potentially limiting noise source in advanced interferometric gravitational wave (GW) detectors. In addition, the method can be used to provide sub-percent calibration in phase and amplitude of modern interferometric GW detectors. Knowledge of calibration to such certainties shall enhance the scientific output of the in...

متن کامل

Seismic gravity-gradient noise in interferometric gravitational-wave detectors

When ambient seismic waves pass near and under an interferometric gravitational-wave detector, they induce density perturbations in the Earth, which in turn produce fluctuating gravitational forces on the interferometer’s test masses. These forces mimic a stochastic background of gravitational waves and thus constitute a noise source. This seismic gravity-gradient noise has been estimated and d...

متن کامل

Optimization of thermal noise in multi-loop pendulum suspensions for use in interferometric gravitational-wave detectors

We study the thermal-noise spectrum of multi-loop pendulum suspensions for test masses in interferometric gravitational-wave detectors. The dependence of the thermal noise on suspension parameters and on properties of the wire material is discussed for the situation in which the losses are dominated by the internal friction in the pendulum wires. PACS: 04.80.Nn; 05.40.Ca; 62.40.+i

متن کامل

Reduction of optimum light power with Heisenberg-limited photon-counting noise in interferometric gravitational-wave detectors

We study how the behavior of quantum noise, presenting the fundamental limit on the sensitivity of interferometric gravitational-wave detectors, depends on properties of input states of light. We analyze the situation with specially prepared nonclassical input states which reduce the photoncounting noise to the Heisenberg limit. This results in a great reduction of the optimum light power neede...

متن کامل

High power, low-noise, and multiply resonant photodetector for interferometric gravitational wave detectors.

We have developed a new photodetector circuit for use in interferometric gravitational wave detectors. The circuit can detect high laser power with low noise and provide multiple outputs for different signal frequencies. The dynamic range of this circuit is increased in comparison with the photodetector design used until the end of 2005.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999